Surface Temperature Measurement Points And Standard Values - Fujitsu MPG3XXXAH Product Manual

Fujitsu computer drive user manual
Table of Contents

Advertisement

(4)
Ambient temperature
The temperature conditions for a disk drive mounted in a cabinet refer to the ambient temperature
at a point 3 cm from the disk drive. Pay attention to the air flow to prevent the DE surface
temperature from exceeding 60°C.
Provide air circulation in the cabinet such that the PCA side, in particular, receives sufficient
cooling.
To check the cooling efficiency, measure the surface temperatures of the DE.
Regardless of the ambient temperature, this surface temperature must meet the standards listed in
Table 3.1. Figure 3.6 shows the temperature measurement point.
1
Figure 3.6
Table 3.1
No.
1
DE cover
3 - 6
Surface temperature measurement points

Surface temperature measurement points and standard values

Measurement point
C141-E112-01EN
Temperature
60°C max

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Mpg3102ahMpg3153ahMpg3204ah

Table of Contents