4.2 Each Filter Use (cont.)
At each scheduled boil-out, disassemble the filter-leaf as described and place in the frypot
filled with boil-out solution (where applicable).
Installation and Operation manual included with the fryer. After boil out is complete, place
the filter-leaf in a vinegar solution (1 pint vinegar to 1/2 gallon water) to neutralize boil-out
residue. Rinse the filter-leaf in clean water to rinse away vinegar residue.
Allow all filter-leaf components to air dry or thoroughly dry with paper towels.
Do not run water or boil-out solution through the filtration system. Doing so
will cause irreparable damage to the pump, and the warranty will be voided.
SUFF/UFF FILTRATION SYSTEMS
4
1
3
CAUTION
4-2
Follow the boil-out procedure in the
Typical filter-leaf assembly in
SUFF/UFF systems so equipped.