PROBLEM
Power Shower is not
spraying properly.
6.6
Replacing the Ignition Module Fuse in Units with Electronic Ignition
1. Disconnect the fryer from the electrical supply and remove the two screws in the upper corners
of the control panel. Swing the panel open from the top, allowing it to rest on its hinge tabs.
2. Locate the 3-amp ignition module fuse (refer to illustration below) and, using a fuse-puller,
remove and replace it with a new fuse.
Depending upon when the unit was
manufactured, full vat units may have either
one or two ignition modules. If there is only
one ignition module, the fuse will be mounted
on the interface board.
Dual vat units and some full vat units will have
two ignigiton modules. Look for the fuse on
the left side of the module. If there are no
fuses on the modules, the fuse will be on the
interface board.
3. Close the panel, replace the control panel screws, and reconnect the fryer to the electrical supply.
PROBABLE CAUSES
A. Plugged openings or solidified
shortening in the Power Shower.
Test: Look for oil/shortening
squirting out around the Power
Shower gasket. If so, Power
Shower is obstructed.
B. Missing/worn O-rings and gasket
on Power Shower.
C. Missing paper in filter pan. (This
causes too much pressure in the
oil return lines, resulting in a
strong flow through the Power
Shower, but also squirting of oil
from around the gasket.)
Ignition Module
CORRECTIVE ACTION
A. Clean the Power Shower per
instructions in Chapter 5 of this
manual.
B. Verify that O-rings and gasket are
present and in good condition.
C. Verify that filter paper is properly
installed in the filter pan.
For units in which the ignition
module has no fuse, replace the
upper fuse on the interface board.
6-6