Gas fryers
Table of Contents

Advertisement

7. Let the filter run 10 to 12 seconds after
oil/shortening stops coming out of the Power
Shower to clear the lines and prevent
shortening from hardening in them. Rotate
the oil return handle to the OFF position to
stop the pump. Remove the Power Shower
and allow it to drain. Turn the fryer on and
allow the cooking oil/shortening to reach
setpoint.
The crumb tray in fryers equipped with a filter system must be emptied into a
fireproof container at the end of frying operations each day. Some food particles
can spontaneously combust if left soaking in certain shortening material.
The filter pump is equipped with a manual reset switch in case the filter motor
overheats or an electrical fault occurs. If this switch trips, turn off power to the filter
system and allow the pump motor to cool 20 minutes before attempting to reset the
switch.
The switch is accessed by pulling the filter assembly out of the fryer cabinet so that
the motor can be reached. The switch is the red button on the face of the motor (see
photo below).
DANGER
WARNING
4-6