6. Basket Lift malfunctions.
The probable causes of each category are discussed in the following sections.
Troubleshooting Guides is included at the end of the chapter to assist in identifying some of the
more common problems.

1.9.1 Pilot Failures

There are two categories: no pilot flame and unreliable flame.
No pilot flame
1. No gas or insufficient gas supply
2. Clogged pilot orifice
3. Air in gas lines ( usually in new installations)
Unreliable flame
1. Open or grounded high limit
2. Loose/corroded wire connections
3. Low or no voltage out of thermopile
4. Bad gas valve

1.9.2 Problems Related to the Gas and/or Electrical Current