Functional Description
Alarm Setting
25. Alarm Setting
25.1. Setting Up Alarm Input
▶ Main Menu/Alarm Setting/Alarm Input
Alarm Enable :
Main Menu
- On/Off : Enables or disables the Alarm function.
① Camera Setting
MOD :
② Sequence Setting
Enables selecting an Alarm Input method.
③ P/T Setting
- NO (Normally Open)
④ OSD Setting
⑤ Alarm Setting
IN 1.2.3.4
⑥ Initialize
Status
➡
Alarm Setting
ALM GND
Alarm Enable
OFF
ALARM OFF
② Alarm Input
③ Alarm Output
④ Aux Output
➡
- NC (Normally Closed)
ALM MOD P SEQ. NO
IN 1.2.3.4
IN1 OFF 1
OFF
IN2 OFF 2
OFF
IN3 OFF 3
OFF
IN4 OFF 4
OFF
ALM GND
ALARM OFF
70
SPEED DOME CAMERA
IN 1.2.3.4
⇨
ALM GND
ALARM ON
IN 1.2.3.4
⇨
ALM GND
ALARM ON
User's Manual
Functional Description
Notes
• A sshowninthepictureabove,theAlarmInputmustbeenteredwiththeOpenandClose
switch signals. Supplying power without entering the signals may damage the product.
P (Priority) :
Set the priority of Alarm Inputs. If more than one alarm is simultaneously activated,
the alarm with the highest priority activates before the others. Once the alarm is canceled, the
next highest priority alarm activates.
SEQ :
Enables setting up a sequence action for the camera in response to an alarm. Available
sequence actions are Preset, Swing, Group, Tour, Trace and A.Pan.
71
SPEED DOME CAMERA
User's Manual