145-3, Sangdaewon-dong, Jungwon-gu, Seongnam-si, Gyeonggi-do, 462-120, Korea TEL : +82-31-740-8151~8158 FAX : +82-31-740-8145 SAMSUNG OPTO-ELECTRONICS UK, LTD. • Samsung House, 1000 Hillswood Drive, Hillswood Business Park Chertsey, Surrey KT16 OPS TEL : +44-1932-45-5308 FAX : +44-1932-45-5325 www.samsungtechwin.com www.samsungcctv.com 10X Day & Night PTZ Dome Camera SPD-1000 Thank you for purchasing a SAMSUNG CCD CAMERA.
Page 2
The lightning flash with an arrowhead symbol, within an equilateral triangle is intended to alert the user to the presence of uninsulated “dangerous voltage” within the product's enclosure that may be of sufficient magnitude to constitute a risk of electric shock to persons. The exclamation point within an equilateral triangle is intended to alert the user to the presence of important operating and maintenance (servicing) instructions in the literature accompanying the appliance.
Page 3
Samsung Techwin cares for the environment at all product manufacturing stages to preserve the environment, and is taking a number of steps to provide customers with more environment-friendly products.The Eco mark represents Samsung Techwin s will to create environment-friendly products, and indicates that the product satisfies the EU RoHS Directive.
Contents Precautions Part Names and Functions Body Main Body Port Block Cable Connection Camera Initial Setting Components and Accessories Installation Functional Description OSD Menu Organization PTZ Camera User Menu Settings 1. Camera Settings 2. Sequence Setting 3. P/T Setting 4. OSD Setting 5.
Precautions Installation by unqualified If any unusual odors or smoke comes persons is not recommended. from the camera, stop using the product. Experienced and skilled technicians have to install It may cause fire. this product. Unqualified and personal installation may cause fire or electric shock. Contact the dealer for installation.
Part Names and Functions Body Main Body Port Block (Rear panel) Power Input Jack Camera ID Setting Switch Communication Protocols, Transmission Mode,Termination Setting Switch Controller and Alarm Input/Output Connection Terminal Auxiliary Video Terminal Cable Connection...
9,600 Reserved Notes • Default Setting : Samsung 9,600 bps • When you set up, refer to rear panel number(Ignore, DIP SWITCH number). • Please see our homepage for details on the protocol Setting Baud Rate Based on DVR Model If the speed dome camera is controlled not by the camera controller but by a DVR, set the communication speed based on the DVR model as follows.
Page 8
Part Names and Functions Setting RS-485 Termination Set the termination using the ON/OFF of #7~#8 of the Rear Panel SW2. Rear panel Number Location of Camera Connection SW2 - #7 Termination of Longest Path On the Path Notes • Factory Setting: OFF •...
Page 9
Part Names and Functions Camera ID SW1-#1 SW1-#2 SW1-#3 SW1-#4 SW1-#5 SW1-#6 SW1-#7 SW1-#8 Camera ID SW1-#1 SW1-#2 SW1-#3 SW1-#4 SW1-#5 SW1-#6 SW1-#7 SW1-#8...
Page 10
Part Names and Functions Camera ID SW1-#1 SW1-#2 SW1-#3 SW1-#4 SW1-#5 SW1-#6 SW1-#7 SW1-#8 Camera ID SW1-#1 SW1-#2 SW1-#3 SW1-#4 SW1-#5 SW1-#6 SW1-#7 SW1-#8...
Page 11
Part Names and Functions SW1-#1 SW1-#2 SW1-#5 SW1-#6 Camera ID SW1-#3 SW1-#4 Connect the controller and alarm input and output signal (main body port block) Pin Order Pin Name Purpose RS-485 Data+ RS-485 Data- Alarm Signal Input Port #1 Alarm Signal Input Port #2 +12V Output Port Alarm Signal Output Port #1 (For Normal Open) Alarm Signal Output Por #1 (For Normal Close)
Components and Accessories Accessories power adapter (DC 12V, Peak 4A) User s Manual 2 installation brackets 3 installation bracket installation cover installation template fixing screws BNC auxiliary cable Products Sold Separately The following products are provided separately. • CONTROLLER Camera Controller : SCC-3100A •...
Page 13
Installation Cable Connection Monitor 1. First, connect one end of the BNC In Terminal video cable connector to the Video Output Terminal. 2. Next, connect the other end of the connector to the Video Input Terminal of the monitor. Monitor 3.
Installation Installing the SPD-1000 on a Ceiling 1. Prepare the accessories in the camera box (power adapter, installation template, BNC auxiliary cable, 1 loose-proof screw, 3 installation bracket fixing screws, 2 installation brackets, installation cover) and a tool for making a hole in the ceiling. power adapter(DC 12V, Peak 4A) installation template BNC auxiliary cable...
Page 15
Installation Installing the SPD-1000 Wall Mount 1. Prepare the accessories in the camera box (power adapter, BNC auxiliary cable, 1 loose-proof screw, 2 installation brackets, installation cover) and the wall mount (STB-280PW or STB-230PW) and 3 installation bracket fixing screws in the mount packaging box.
Installation 5. To complete installation, rotate the installation cover along the groove of the ceiling attachment bracket, and fix it. Wall Installing the Dome Housing (STH-1000PI) To install the Dome Housing (STH-1000PI), fix it instead of installing the cover in the last step “Installing the SPD-1000 on a Ceiling” on page 26 and “Installing the SPD-1000 Wall Mount”...
Functional Description Symbol Description 1. Motion Stabilization Stand-by Operation - “Man Icon” is flashing on the right top of the - “D” symbol is flashing on the right top of screen. the screen. 5. When there are sub menus under the 2.
Page 19
Functional Description White Balance The White Balance function corrects the abnormal white colour into the normal white colour under any colour temperature lighting. Select the mode among ATW, AWC and Manual. ATW is selected by default. Camera Setting Focus White Balance ATW(O) Exposure Back Light...
Page 20
Auto Focus function may not work. Back Light Unlike other cameras, Samsung Techwin’s unique W-III DSP chip gives you a clear image of the subject even with bright backlight. Camera Setting...
Page 21
Functional Description Day & Night The darkness level is detected automatically under low light conditions such as at night or under dark light to keep the screen bright and clear. Camera Setting Camera Setting Focus Focus White Balance ATW(O) White Balance Exposure Exposure Back Light...
Functional Description 2) Sequence Setting • Sequence Setting Menu Sequence Setting Preset Preset Setting Swing SEQ Edit Group SEQ Execute Tour SEQ Clear PTZ Trace Status Auto Run Power On Resume OFF Preset : 12 items such as Pan/Tilt location, Zoom and Focus are selected among camera functions and they can be called for monitoring.
Page 23
Functional Description 6. If you select the Scene Adj. item, such items Scene Adj. as Shutter, AGC, SSNR, Sens-Up, White Shutter Balance can be set up differently in every SSNR Preset item. Sens-Up White Balance Notes • In the White Balance setting of the individual Preset Scene Adj., the AWC selection is not available.
Functional Description PTZ Trace : Maximum 4 patterns of the manual operation paths (for Pan, Tilt, Zoom and Focus) are memorized and replayed. Sequence Setting PTZ Trace Preset Trace 1 Swing SEQ Trace 2 Group SEQ Trace 3 Tour SEQ Trace 4 PTZ Trace Auto Run...
Page 25
Functional Description Tilt Limit : Moving range in the tilt direction can be limited. Main Menu P/T Setting Camera Setting Pan Limit Sequence Setting Tilt Limit P/T Setting Area Setting OSD Setting Area Masking Alarm Setting Prop. P/T Initialize Digital Flip Status Jog Speed Position : Moving range can be set up.
Functional Description Digital Flip : When you operate the Tilt up to 100˚ limit using the joystick and keep it for a certain time, the image gets reversed automatically and the opposite Tilt area is seen. When you want to monitor the moving object under the camera, execute the Digital Flip function using the controller’s joystick.
Page 27
Functional Description Preset Number (Default setting is ON.) : Preset numbering is set up. OSD Setting Main Menu Camera ID Camera Setting Camera Name Sequence Setting Preset Number P/T Setting Preset Name OSD Setting Sequence Status ON Alarm Setting Area Name Initialize PTZ Position Status...
Functional Description Language : The OSD can be displayed either in English (default setting) , Chinese, French, German, Italy and Spanish Main Menu OSD Setting Camera Setting Camera ID Camera Name Sequence Setting Preset Number P/T Setting Preset Name OSD Setting Sequence Status OFF Alarm Setting Area Name...
Camera Status CAM MODER = 10NC CAM VERSION = 4.6 DOME VERSION = 1.00 CON PROTOCOL = SAMSUNG TW DOME ID = 001 CONTROLLER = Duplex-9600 Camera Model Camera S/W Version Control Board S/W Version Dome Camera ID...
Product Structure and Installation Installation 2 (Mini PTZ Dome Camera Control) Specifications SPD-1000N Imaging device 1/4” Color Interline Transfer CCD. NTSC 811(H) X 508(V) Total Number of Pixels Valid Pixel 768(H) X 494(V) 15.734kHz Horizontal Scan Frequency Vertical Scan Frequency 59.94Hz Synchronization Internal Sync...
* The product design and dimensions may change without previous notice for improvement of performance. • The copyright of this manual belongs to Samsung Techwin Co. Ltd. • Parts or the whole of this manual cannot be reproduced or transmitted by any electric, mechanic or audio method without the authorized written approval of Samsung Techwin.