SW046
Ladder Scan Time
S0034
Ladder Instruction Error
Status
Configuration Words and coils
Register / Coil
Tag Name
MW0000
PLC Operation Mode
(Bit 0 to Bit 3)
MW0001
Error Register 1
MW0002
Error Register 2
MW0003
RUN/STOP Switch Control
(Retentive)
MW0005
Digital Filter constant
MW0010
Configuration Register for
Special inputs
MW0011
Configuration Register for
PWM output
MW0012
Preset values for high Speed
MW0013
Counter
MW0014
MW0015
MW0016
Count Values for high Speed
Counter
MW0017
MW0018
MW0019
MW0020
High Speed counter
control flags
MW0021
Special output control flags
MW0022
Special Output Control Flags Read/Write
MW0023
MW0024
Special output Frequency
Setting
MW0025
MW0030
System Timer Coils
MW0031
User Interrupt program Status
Flags
MW0033
Unit IP Address Lo Word
MW0034
Unit IP Address Hi Word
MW0035
Unit Subnet Mask Address
Lo Word
MW0036
Unit Subnet Mask Address
Hi Word
MW0037
Unit Default Gateway
Lo Word
MW0038
Unit Default Gateway
Hi Word
M00016
CPU error
M00017
I/O error
M00018
Program error
Read only
Value is multiple of 0.1 mSec
Read/Write
Set if Division by zero operation is performed in
the ladder instruction and for invalid conditions or
operands in case of conversion instructions.
Read / Write Description
Bit0-3: 0: Initialization 1: HALT Mode 2: RUN
Read/Write
Mode 3: RUN-F Mode 4: HOLD Mode 6: ERROR
Mode.
Read Only
Refer mapped coils M16 to M31
Read Only
Refer mapped coils M32 to M47
Read Only
1: HALT, 0: RUN. Only LSB is used. other bits (1
to 15) are not used.
Read/Write
Enabled when MW10 bit 16 is ON.
(0 to 15 mS)
Read/Write
Refer Special input - output section
Read/Write
Refer Special input - output section
Read/Write
Used to set the preset values for high speed
counter
Read/Write
Preset count values of the high speed counters
are stored
Read/Write
Control flags for high speed counters
Read/Write
Refer Special input - output section
Control flags for high speed counters
Read/Write
Refer Special input - output section
Read Only
Refer mapped coils M00480 to M00487
Read Only
Bit 0 for timer ,Bit 1 for IO1, Bit 2 for IO2. Refer
mapped coils M496,M497 & M498
when MW10 bit 16 is ON.
Read Only
Used for Ethernet Model
Read Only
Read Only
Read Only
Read Only
Read Only
Read Only
ON at error state
Read Only
ON at error state
Read Only
ON at error state. This group includes Ladder
Scan time.