8.1.5

Test programs

Special functions can be triggered in the appliances by
activating various test programs. These programs are
given in detail in the table below.
• The test programs P.0 to P.6 are started when "Power
ON" is turned on and the "+" key is pressed for 5 s.
The display shows "P.1".
• Press the "+" key to start counting the test number
upwards.
• Press the "i" to operate the appliance now and to
start the test program.
• Press "i" and "+" simultaneously to exit the test pro-
grams. You can also end the test programs by not
pressing any key for 15 minutes.
Display
Meaning
P.0
Venting test program
1x "i" key: start venting the heating pump
(display: HP)
2x "i" key: start venting the charging pump
(display: LP)
3x "i" key: end venting program
Note: the venting program runs for approx. 6.5 mins.
P.1
Test program where the appliance is operated in full
load after successful ignition
P.2
Test program whereby the appliance is operated with
minimum gas volume after successful ignition
P.5
Test program for safety thermostat test; appliance
heats up by bypassing a control shutdown until the
safety thermostat shutdown temperature of 97 °C is
reached
36
9
Vaillant Service
To ensure efficient and reliable operation of your boiler
it is recommended that regular servicing is carried out
by your service provider.
Vaillant Applied System Sales
Vaillant Ltd., Unit D1 Lowfields Business Park, Elland.
West Yorkshire. HX5 9DG
Training
Telephone 01634 - 29 23 70
Fax
01634 - 29 23 54
email
training@vaillant.co.uk
Commercial Service
Telephone 0870 - 8 50 30 72
Mon - Fri
8.30 - 17.30
Fax
01773 - 52 59 46
email
aftersales @ vaillant.co.uk
10 Recycling and disposal
Recycling and disposal have already been taken into ac-
count during the development of all Vaillant products.
Vaillant's standards lay down strict requirements.
When selecting materials, the recyclability, dismounta-
bility and separability of materials and components are
taken into account, just as environmental hazards and
health risks during recycling and the disposal of una-
voidable remains of unusable residue are.
10.1

Appliance

The Vaillant ecoMAX 665 consists 92 % of metallic ma-
terials which can be melted down again at iron and steel
works and therefore can be recycled practically any
number of times. The plastic materials used are labelled
and, in this way, are already prepared for sorting and
fractionation for subsequent recycling.
10.2

Packaging

Vaillant has reduced the transport packaging of the ap-
pliances to a minimum. The strict selection of the pack-
aging materials is based on their recyclability.
The high-quality cardboard articles are secondary raw
materials which have been in demand in the cardboard
and paper industry for a long time.
The EPS (polystyrene)® used is necessary to protect
the products during transport. EPS is 100 % recyclable
and CFC-free.
The films and tightening bands are also made of recy-
clable plastic.