UNI-T UT361 Operating Manual

UNI-T UT361 Operating Manual

Anemoscope
Hide thumbs Also See for UT361:

Advertisement

Advertisement

Table of Contents
loading

Summary of Contents for UNI-T UT361

  • Page 1: Table Of Contents

    UT361/UT362 OPERATING MANUAL Table of Contents Title Page Overview Unpacking Inspection Rules For Safety Operation The Anemoscope Structure Display Symbols Setting Up The Anemoscopes Using The Anemoscopes Measuring Wind Speed Computer Connectivity (For UT362 only) Maintenance Technical Specification...
  • Page 2: Overview

    (VEL + Temperature, Flow + Area) Model UT361 and UT362 come with the real time wind speed measurement, including m/s, km/h, ft/min, MPH, KNOT, CFM, CMM as measuring units. In addition, it can provide maximum value, minimum value, average value record, Centigrade temperature and Fahrenheit temperature.
  • Page 3: Unpacking Inspection

    UT361/UT362 OPERATING MANUAL Warning To avoid electric shock or personal injury, read the "Rules for Safe Operation" carefully before using the Anemoscope. Unpacking Inspection Open the package case and take out the Meter. Check the following items carefully to see any missing or damaged part:...
  • Page 4: Rules For Safety Operation

    UT361/UT362 OPERATING MANUAL In the event you find any missing or damage, please contact your dealer immediately. In this manual, a Warning identifies conditions and actions that pose hazards to the user, or may damage the anemoscopes or the equipment under test.
  • Page 5 UT361/UT362 OPERATING MANUAL To avoid possible electric shock or personal injury and to avoid possible damage to the anemoscopes or to the equipment under test, adhere to the following rules Do not use your hand to touch the fan and / or the measurement of wind count...
  • Page 6 UT361/UT362 OPERATING MANUAL Use the specific authorized replacement part if you need to repair the anemoscopes Do not use the anemoscopes if the opening the housing cover Note the battery " + " and " - "pole when battery insert.
  • Page 7: The Anemoscope Structure

    UT361/UT362 OPERATING MANUAL The Anemoscope Structure (see figure 1) Wind Speed Indicator Handle Secondary Display Primary Display Power Button Operational Button Main Unit Figure 1...
  • Page 8: Display Symbols

    UT361/UT362 OPERATING MANUAL Display Symbols (see figure 2) Figure 2...
  • Page 9 UT361/UT362 OPERATING MANUAL Functional Signs Below table indicated for information about the functional sign operations. Number Sign Meaning Display of Maximum Reading Display of Minimum Reading Data Hold is on Display of Average Reading READ Display of Data Storage Measurement Reading REC NO.
  • Page 10 UT361/UT362 OPERATING MANUAL Number Sign Meaning Secondary Data Display Primary Data Display ft/min Wind Speed Unit - Foot Per Minute Wind Speed Unit - Meter Per Second Fahrenheit Temperature Signal / Centigrade Temperature Signal Cubic Feet Per Second Cubic Meter Per Minute...
  • Page 11 UT361/UT362 OPERATING MANUAL Display Symbols (see figure 3) Function Key Description Power on / Power off Button Button 1 - This button function key switch is for wind speed measurement and wind count measurement. During wind speed measurement, press "UNIT"...
  • Page 12 UT361/UT362 OPERATING MANUAL Description Function Key Button 2 - Press this button to choose In wind speed measurement: maximum reading, minimum reading and the instant measuring unit exchange In wind count measurement: maximum reading, minimum reading, average reading, 2/3V maximum value and instant measurement units exchange.
  • Page 13 UT361/UT362 OPERATING MANUAL Function Key Description Button 7 - Press this button to activate the REC feature. Press and Hold this button to access data reading from database Button 8 - Press this button to erase the data records before power on.
  • Page 14: Setting Up The Anemoscopes

    UT361/UT362 OPERATING MANUAL Setup up the Anemoscopes Press and hold button 9 (menu) to select feature setup. Press next button to go next feature sub-menu. USB setup Press button 8 from USBO USB1. Then set up is as the opening default...
  • Page 15 UT361/UT362 OPERATING MANUAL This default keep it and no need to reset when power on. Master Reset LCD shows the DEF with flash. You can reset your anemoscopes to the factory settings. Press button 2 of to the factory settings for USBO, APO1, 60S data clearing. Press...
  • Page 16: Using The Anemoscopes

    UT361/UT362 OPERATING MANUAL Using the Anemoscopes Power On: Press "Power " button for a while to switch the anemoscopes on Wind Speed and Wind Count Feature Switch: Press VEL / FLOW button. VEL (wind speed) to FLOW (wind count) Data Hold: Press " Hold " button to data capture, then press again to cancel the data capture feature.
  • Page 17 UT361/UT362 OPERATING MANUAL Wind pipe input area: 1) Correct input the wind pipe area before wind count measurement 2) Set default area is one square meter after the entering wind count measurement. 3) Select the approiate wind count-measuring unit. The press " Sample " button to enter area input.
  • Page 18 UT361/UT362 OPERATING MANUAL Enter 1, ENTET Mean 1 LCD display " 1.000 " Enter 0, 0, 0, 1 Mean 0001 LCD display " 1.000 " Enter ., 0, 0, 1 Mean . 001 LCD display " 0.001 " ..
  • Page 19 UT361/UT362 OPERATING MANUAL Data Storage Functions: 1) LCD display " No Data " if no data storage 2) LCD display " Time " if database is full and cannot store any data in the current time. 3) Manual data storage: press button 7 to display the automatic data storage in LCD, also LCD displays REC and around 0.5 seconds to disappear "...
  • Page 20 UT361/UT362 OPERATING MANUAL 5) Record Clearing Method 1: Press and hold button 8 until LCD appear CLR when power on. Method 2: Resume to factory setting (see function setting stuff) Press and hold button 7 to view the data records of wind speed measurement and wind count measurement.It automatically display last data record.
  • Page 21: Measuring Wind Speed

    UT361/UT362 OPERATING MANUAL Measuring For Wind Speed (Wind Count) (see figure 4) Note: before use, the wind speed is over 10m/s under 1 - 2 minutes duration. To carry out anemoscopes, follow the following procedure: Press on " Power " button until the...
  • Page 22 Warning do not use it in opposite. A screw can fix on it. (Note: UNI-T will not provide this screw to the customer, the customer need to buy it separately) Wait for 2 seconds to obtain a more precise reading during the connection between wind speed measurement and wind source.
  • Page 23: Computer Connectivity (For Ut362 Only)

    UT361/UT362 OPERATING MANUAL Computer Connectivity (For UT362 only)(see figure 5) When use the anemoscopes model UT362 need to connect USB cable with the computer Connect the USB interface cable, the anemoscope and the computer as reference to the figure 5...
  • Page 24: Maintenance

    UT361/UT362 OPERATING MANUAL Maintenance Replacing The Battery To avoid false reading, which could read to possible electronic shock or personal injury, replace the battery as soon as the battery indicator " " appears. To replace the battery Turn the anemoscope off and remove all the connections from the...
  • Page 25 UT361/UT362 OPERATING MANUAL Rejoin the case bottom and the battery compartment and reinstall the screw. Cleaning Periodically wipe the case with a damp cloth and mild detergent. Do not use abrasives or solvents. Service And Repairing This anemoscope is an auto calibration. Do not attempt to repair or service...
  • Page 26 UT361/UT362 OPERATING MANUAL Take out the battery when it is not using for a long time. Do not use or store the Meter in a place of humidity, high temperature, explosive, inflammable and strong magnetic field. Environmental Requirements Operating Temperature Range:...
  • Page 27: Technical Specification

    UT361/UT362 OPERATING MANUAL Technical Specification Wind Speed Measurement Range Accuracy UT361 UT362 2~10 m/s (3%+0.5) (3%+0.5) 10~30 m/s (3%+0.8) (3%+0.8)
  • Page 28 UT361/UT362 OPERATING MANUAL Temperature Measurement Temperature Range Accuracy UT361 UT362 Main Unit Temperature ~ 104 Sensor Temperature ~ 104 ** END **...
  • Page 29 UT361/UT362 OPERATING MANUAL This operating manual is subject to change without notice.
  • Page 30 UT361/UT362 OPERATING MANUAL...