Location Of Your Dryer - Frigidaire 137101400 Installation Instructions Manual

27 inch gas dryer
Table of Contents

Advertisement

Available languages

Available languages

Venting vertical through a roof may expose the exhaust system
to down drafts causing an increase in vent restriction.
Running the exhaust system through an uninsulated area may
cause condensation and faster accumulation of lint.
Compression or crimping of the exhaust system will cause an
increase in vent restriction.
The exhaust system should be inspected and cleaned a minimum
of every 18 months with normal usage. The more the dryer is
used, the more often you should check the exhaust system and
vent hood for proper operation.
EXHAUST DIRECTION
All dryers shipped from the factory are set up for rear exhausting.
However, on electric dryers, exhausting can be to the right or left
side of the cabinet or the bottom of the dryer. On gas dryers,
exhausting can be to the right side of the cabinet or the bottom of
the dryer. Directional exhausting can be accomplished by install-
ing Exhaust Kit, P/N 131456800, available through your parts dis-
tributor. Follow the instructions supplied with the kit.
EXHAUST DUCT LOCATING DIMENSIONS
SAME AS OTHER SIDE
SAME AS OTHER SIDE
SAME AS OTHER SIDE
SAME AS OTHER SIDE
SAME AS OTHER SIDE
3 3/4"
3 3/4"
3 3/4"
3 3/4"
3 3/4"

LOCATION OF YOUR DRYER

DO NOT INSTALL YOUR DRYER:
1. In an area exposed to dripping water or outside weather
conditions.
2. In an area where it will come in contact with curtains, drapes,
or anything that will obstruct the flow of combustion and
ventilation air.
3. On carpet. Floor MUST be solid with a maximum slope of 1
inch (2.54 cm).
INSTALLATION IN RECESS OR CLOSET
1. A dryer installed in a bedroom, bathroom, recess or closet,
MUST be exhausted outdoors.
2. No other fuel burning appliance shall be installed in the same
closet as the Gas dryer.
3. Your dryer needs the space around it for proper ventilation.
DO NOT install your dryer in a closet with a solid door.
4. A minimum of 120 square inches (774.2 square cm) of opening,
equally divided at the top and bottom of the door, is required.
Air openings are required to be unobstructed when a door is
installed. A louvered door with equivalent air openings for the
full length of the door is acceptable.
5 7/8"
5 7/8"
5 7/8"
5 7/8"
5 7/8"
4 3/8"
4 3/8"
4 3/8"
4 3/8"
4 3/8"
13 1/2"
13 1/2"
13 1/2"
13 1/2"
13 1/2"
3 3/4"
3 3/4"
3 3/4"
3 3/4"
3 3/4"
(9.5 cm)
(9.5 cm)
(9.5 cm)
(9.5 cm)
(9.5 cm)
MINIMUM INSTALLATION CLEARANCES - Inches (cm)
SIDES
REAR
Alcove 0 (0 cm) 0 (0 cm)
Closet
0 (0 cm) 0 (0 cm)
Closet door ventilation required: 2 louvered openings each 60
square inches (387 square centimeters) — 3 inches (7.6 cm) from
bottom and top of door.
This dryer MUST be exhausted outdoors.
5. The following illustrations show minimum clearance dimensions
for proper operation in a recess or closet installation.
0" (0 cm)
5
TOP FRONT
1 (2.54 cm)
60 sq. inches
(387.1 sq. cm)
60 sq. inches
(387.1 sq. cm)
CLOSET DOOR
0" (0 cm)
1" (2.54 cm)
0" (0 cm)

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Fgq1452hGlgq2152eGq1442es

Table of Contents