Frigidaire 137101400 Installation Instructions Manual page 4

27 inch gas dryer
Table of Contents

Advertisement

Available languages

Available languages

- Risk of Fire - A clothes dryer must be ex-
hausted outdoors. Do not exhaust dryer into a chimney, a
wall, a ceiling, an attic, a crawl space or any concealed space
of a building. A clothes dryer produces combustible lint. If the
dryer is not exhausted outdoors, some fine lint will be expelled
into the laundry area. An accumulation of lint in any area of the
home can create a health and fire hazard. The dryer must be
connected to an exhaust outdoors. Regularly inspect the
outdoor exhaust opening and remove any accumulation of lint
around the outdoor exhaust opening and in the surrounding
area.
Do not allow combustible materials (for ex-
ample: clothing, draperies/curtains, paper) to come in con-
tact with exhaust system. The dryer MUST NOT be exhausted
into a chimney, a wall, a ceiling, or any concealed space of a
building which can accumulate lint, resulting in a fire hazard.
Exceeding the length of duct pipe or num-
ber of elbows allowed in the "MAXIMUM LENGTH" charts
can cause an accumulation of lint in the exhaust system. Plug-
ging the system could create a fire hazard, as well as increase
drying times.
Do not screen the exhaust ends of the vent
system, nor use any screws, rivets or other fastening means
that extend into the duct and catch lint to assemble the
exhaust system. Lint can become caught in the screen, on the
screws or rivets, clogging the duct work and creating a fire haz-
ard as well as increasing drying times. Use an approved vent
hood to terminate the duct outdoors, and seal all joints with duct
tape. All male duct pipe fittings MUST be installed downstream
with the flow of air.
Explosion hazard. Do not install the dryer
where gasoline or other flammables are kept or stored. If
the dryer is installed in a garage, it must be a minimum of 18
inches (45.7 cm) above the floor. Failure to do so can result in
death, explosion, fire or burns.
of 4" (10.2 cm) Dia. Rigid Metal Duct
(Preferred)
Number
of
90°
Turns
4"
(10.2 cm)
0
60 ft.(18.28 m)
1
52 ft.(15.84 m)
2
44 ft.(13.41 m)
3
32 ft.(9.75 m)
4
28 ft.(8.53 m)
of 4" (10.2 cm) Dia. Flexible Metal Duct
Number
of
(Preferred)
90°
Turns
4"
(10.2 cm)
0
30 ft.
1
22 ft.
2
14 ft.
3
CORRECT
INSTALL MALE FITTINGS IN CORRECT DIRECTION
In installations where the exhaust system is not described in the
charts, the following method must be used to determine if the
exhaust system is acceptable:
1. Connect an inclined or digital manometer between the dryer
and the point the exhaust connects to the dryer.
2. Set the dryer timer and temperature to air fluff (cool down)
and start the dryer.
3. Read the measurement on the manometer.
4. The system back pressure MUST NOT be higher than 0.75
inches of water column. If the system back pressure is less
than 0.75 inches of water column, the system is acceptable.
If the manometer reading is higher than 0.75 inches of water
column, the system is too restrictive and the installation is
unacceptable.
Although vertical orientation of the exhaust system is acceptable,
certain extenuating circumstances could affect the performance
of the dryer:
Only the rigid metal duct work should be used.
4
MAXIMUM LENGTH
VENT HOOD TYPE
Louvered
(6.35 cm)
48 ft.(14.63 m)
40 ft.(12.19 m)
32 ft. (9.75 m)
24 ft. (7.31 m)
16 ft. (4.87 m)
MAXIMUM LENGTH
VENT HOOD TYPE
Louvered
(6.35 cm)
(9.14 m)
18 ft. (5.49 m)
(6.71 m)
14 ft. (4.27 m)
(4.27 m)
10 ft. (3.05 m)
NOT RECOMMENDED
INCORRECT
2½"
2½"

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Fgq1452hGlgq2152eGq1442es

Table of Contents