Location Of Your Dryer - Frigidaire AGQ6700FE2 Installation Instructions Manual

Gas & electric dryer
Hide thumbs Also See for AGQ6700FE2:
Table of Contents

Advertisement

Available languages

Available languages

Venting vertical through a roofmay expose t heexhaust system to down
drafts causing a nincrease inventrestriction.
Running the exhaust s ystem throughan uninsulated a reamaycause
condensation andfaster a ccumulation of lint.
Compression
orcrimping of theexhaust system will cause anincrease in
ventrestriction.
Theexhaust system should beinspected andcleaned a minimum of
every 18
months with normal usage. The more the dryer is used, the more often you
should check the exhaust system and vent hood for proper operation.
EXHAUST DIRECTION
All dryers shipped from the factory are set up for rear exhausting. However, on
electric dryers, exhausting can be to the right or left side of the cabinet or the
bottom of the dryer. On gas dryers, exhausting can be to the right side of the
cabinet or the bottom of the dryer. Directional exhausting can be accomplished
by installing Exhaust Kit, P/N 131456800, available through your parts distribu-
tor. Follow the instructions supplied with the kit.
EXHAUST DUCT LOCATING DIMENSIONS
4 3/8"
3 3/4"
3 3/4"
LOCATION
OF YOUR
DRYER
DO NOT INSTALL YOUR DRYER:
1. In an area exposed to dripping water or outside weather conditions.
2. In an area where it will come in contact with curtains, drapes, or anything
that will obstruct the flow of combustion and ventilation air.
3. On carpet. Floor MUSTbe solid with a maximum slope of 1 inch (2.54 cm).
INSTALLATION IN RECESSOR CLOSET
1. A dryer installed in a bedroom, bathroom,
recess or closet, MUST be
exhausted outdoors.
2. No other fuel burning appliance shall be installed in the same closet as the
Gas dryer.
3. Your dryer needs the space around it for proper ventilation.
DO NOT install your dryer in a closet with a solid door.
4. A minimum of 120 square inches (774.2 square cm) of opening, equally
divided at the top and bottom of the door, is required. Air openings are
required to be unobstructed when a door is installed. A Iouvered door with
equivalent air openings for the full length of the door is acceptable.
MINIMUM
INSTALLATION CLEARANCES - Inches (cm)
SIDES
REAR
TOP FRONT
Alcove
0(0cm)
0(0cm)
Closet
0 (0 cm) 0 (0 cm)
1 (2.54 cm)
Closet door ventilation required: 2 Iouvered openings each 60 square inches
(387 square centimeters) -- 3 inches (7.6 cm) from bottom and top of door.
This dryer MUST be exhausted
outdoors.
5 The following illustrations show minimum clearance dimensions for proper
operation in a recess or closet installation.
5
CLOSET DOOR
il
ii
==
--_,*--0
(Ocm)
H
II
II
1 ==
II
_11 _
0"(0,, cm)
(2.54 cm)
_,,4