Evacuated Tube Collector
East West Array
THESE INSTRUCTIONS SHOULD BE READ IN CONJUNCTION WITH THE
Baxi Solarflo
TM
Installation Guide (Part No. 5130226) and Commissioning Guide (Part No. 5130227).
I N S TA L L AT I O N & C O M M I S S I O N I N G
G U I D A N C E N O T E S
The User Guide
(Part No. 5130229) covers the
controller functionality of this kit.
External fixing methods for
Pitched Roof, 'A' Frame or
Facade Floor are covered in the
instructions (Part No. 5130229,
5130330, 5130331)
Please leave these instructions with the
User for Safe Keeping

Advertisement

loading

Summary of Contents for Baxi MULTIFIT Evacuated Tube Collector

  • Page 1 G U I D A N C E N O T E S Evacuated Tube Collector East West Array THESE INSTRUCTIONS SHOULD BE READ IN CONJUNCTION WITH THE Baxi Solarflo Installation Guide (Part No. 5130226) and Commissioning Guide (Part No. 5130227). The User Guide (Part No. 5130229) covers the controller functionality of this kit.
  • Page 2 Content Section Page Introduction to Solar Filling Commissioning of Hydraulic Station Pump & Sensor Connections The East West Array options are only for use with the existing collector sets. If correct system sizing demands that 30 tubes are necessary, then 20 tubes must be fitted to the west facing roof aspect and 10 tubes to the east roof aspect.
  • Page 3: Introduction To Solar

    Where additional transfer fluid is required, it is available under the part no. 5130225 (20 litres) as a accessory. Only this approved Baxi fluid should be used on system and must not be used with other types of fluid or diluted. Failure to observe these requirements will invalidate the product warranty.
  • Page 4 2.0 Flushing & Filling the System Filling the East/West pump station When using the Multifit Electric Filling Pump (Part No 5130234) or the Multifit Manual Filling Pump (Part No 5122761). 1. Ensure the pump is primed with Solar fluid prior to 1 (Fill Valve) commencing filling procedure.
  • Page 5 2.0 Flushing & Filling the System Completing the System fill of the Solar Pump Station with Controller 45° 1. Connect the filling pump to the solar pump station with controller, on the fill and drain valve on the safety group (Fig. 2 item1) and connect the drain hose to the fill and drain valve on the flow meter, (Fig.
  • Page 6 2.0 Flushing & Filling the System Completing the System fill of the Solar Pump Station with Controller (cont) 16. Press the right button (Fig. 2a item 5) twice to select the manual operation menu ( ). Press the down button and the ‘pump’...
  • Page 7 3.0 Commissioning of hydraulic stations Checking and adjusting the flow rate East / West 1. Adjust the flow rate when the system is cold (20°C) (see Fig. 5). 2.The flow rate should be adjusted to give the optimum flow. 3. Manually operate the solar pump (see section 2.2 paragraph 16).
  • Page 8 Conditions of Sale which are available on request. parameter 4 (East/West Array). MULTIFIT A Registered Trademark of Baxi Heating UK Ltd (3879156) A Division of Baxi Group Brooks House, Coventry Road,Warwick. CV34 4LL After Sales Service and Technical Enquiries 08700 603261 Our contact centre is open Monday to Friday 8am to 6pm, Weekends and Bank Holidays 8.30am to 2pm.