Friedrich racservmn Service Manual page 6

Friedrich air conditioner model number: racservmn
Table of Contents

Advertisement

PERFORMANCE
DATA*
Cooling
RS10J10-C
RS12J10A-B
RS15J10-A
RS16J30A-A
RS18J30-A
RM24J30-A
PERFORMANCE
DATA*
Cooling
YS09J10B-A
YS12J33-A
YM18J34B-A
YL24J35C-A
* Rating Conditions: 80 degree F. Room Air Temperature and 50% Relative Humidity with
6
RS-RM PERFORMANCE DATA
EVAPORATOR AIR
TEMP. DEG. F.
Discharge
Temp.
Suction Discharge
Air
Drop F.
61
19
57
23
57
23
56.5
24
56
24
57
23.65
YS-YM-YL PERFORMANCE DATA
EVAPORATOR AIR
TEMP. DEG. F.
Discharge
Temp.
Suction Discharge
Air
Drop F.
59
21
56
24
53
27
55
25
95 degree F. Outside Air Temperature at 40% Relative Humidity.
OPERATING
ELECTRICAL
PRESSURES
Amps
82
248
7.5
83
271
9.8
77
279
11.1
77
296
7.2
72
293
8.7
68
301
12.2
OPERATING
ELECTRICAL
PRESSURES
Amps
90
243
7.7
80
264
5.2/5.6
74
284
8.7/9.2
72
260
10.0/12.0
R-22
RATINGS
REFRIG.
Locked
Charge in
Rotar Amp
OZ.
44
26
54
30
42
29.5
42
30
42
48
44
54
R-22
RATINGS
REFRIG.
Locked
Charge in
Rotar Amp
OZ.
39.2
25
30
28
42
54
61
74
BREAKER
FUSE
60 Hertz
Amps
15
15
15
15
15
15
BREAKER
FUSE
60 Hertz
Amps
15
20
30
30

Hide quick links: