PERFORMANCE DATA
(Heating)
BTUH
@70°F Inside 62°F Outside
@70°F Inside 57°F Outside
@70°F Inside 52°F Outside
**
@70°F Inside 47°F Outside
@70°F Inside 42°F Outside
@70°F Inside 37°F Outside
@70°F Inside 35°F Outside
Evaporator Air Temperature Rise
@70°F Inside 62°F Outside
@70°F Inside 57°F Outside
@70°F Inside 52°F Outside
**
@70°F Inside 47°F Outside
@70°F Inside 42°F Outside
@70°F Inside 37°F Outside
@70°F Inside 35°F Outside
AMPS
@70°F Inside 62°F Outside
@70°F Inside 57°F Outside
@70°F Inside 52°F Outside
**
@70°F Inside 47°F Outside
@70°F Inside 42°F Outside
@70°F Inside 37°F Outside
@70°F Inside 35°F Outside
Watts
@70°F Inside 62°F Outside
@70°F Inside 57°F Outside
@70°F Inside 52°F Outside
**
@70°F Inside 47°F Outside
@70°F Inside 42°F Outside
@70°F Inside 37°F Outside
@70°F Inside 35°F Outside
Suction/Head PSIG
@70°F Inside 62°F Outside
@70°F Inside 57°F Outside
@70°F Inside 52°F Outside
**
@70°F Inside 47°F Outside
@70°F Inside 42°F Outside
@70°F Inside 37°F Outside
@70°F Inside 35°F Outside
*
Heating Element comes on at 35°F outside ambient and compressor shuts off.
** AHAM Rating Conditions.
*WY09A33F-A
9700
9300
8800
8200/8100
7600
6800
11000/9100
32.00
30.75
29.10
27.10/26.80
25.10
22.50
36.40/30.10
4.0
3.9
3.85
3.8/4.1
3.6
3.4
16.0/14.7
880
870
860
835/810
800
760
3550/2950
66/315
62/285
57/285
53/265
49/215
45/203
44/200
*WY12A33F-A
12400
12000
11400
10800/10400
10000
9000
11000/9100
37.60
36.40
34.50
32.70/31.50
30.30
27.30
33.30/27.60
5.6
5.5
5.4
5.3/5.6
5.1
4.8
16.0/14.7
1280
1260
1220
1175/1155
1130
1070
3550/2950
61/325
59/290
53/275
49/255
45/240
41/220
40/215