PROBLEM
Outside water leaks.
PROBLEM
POSSIBLE CAUSE
Insufficient air circulation in air condi-
tioned area.
High indoor
Oversized unit.
humidity.
Inadequate vapor barrier in building
structure, particularly floors.
POSSIBLE CAUSE
Evaporator drain pan cracked or
obstructed.
Water in compressor area.
Obstructed condenser coil.
Fan blade and slinger ring improperly
positioned.
TO CORRECT
Repair, clean or replace as required.
Detach shroud from pan and coil. Clean and
remove old sealer. Reseal, reinstall and check.
Steam clean.
Adjust fan blade to 1/2" clearance from condenser
coil.
TO CORRECT
Adjust louvers for best possible air circulation
Operate in "Fan-Auto (MoneySaver)" position.
Advise customer.