Special Function; Accessories And Replacement Parts; Specifications - Honeywell FOCUSPRO TH5320C Installation Manual

Non-programmable digital communicating thermostat
Table of Contents

Advertisement

Available languages

Available languages

System test
70
Thermostat information
(for reference only)
CAUTION: Compressor protection is bypassed during testing. To prevent equipment
damage, avoid cycling the compressor quickly

Special function

Auxiliary heat control (Setup Function 26):
• Comfort Setting: The thermostat will prioritize comfort over economy depending on heat
pump performance, load conditions and whether the thermostat is calling for the heat
pump. Raising the temperature just a few degrees will often activate the auxiliary heat.
• Economy Setting: The thermostat will attempt to reach the temperature setting
without activating the auxiliary heat. The thermostat will wait to activate the auxiliary
heat depending on heat pump performance, load conditions and how many degrees the
temperature setting is changed.
Diagnostic Codes (Setup Function 19):
When Error Codes are present the home screen of the thermostat will display "SERVICE NEEDED"
and scroll through all active error codes. Setup Function 19 will display a list of the 10 most recent
error codes, both active and inactive. The number on the right of the thermostat will show the
number of active and inactive error codes saved in the thermostat. To view the error codes press
the up arrow. To clear the list, press and hold both the up and down arrow keys. Active errors can
not be cleared; the source of the error must be resolved prior to clearing from the list.
Accessories & replacement parts
Please contact your distributor to order replacement parts.
Part Description
Small cover plate assembly*
Medium cover plate assembly*
12 pack of small cover plates*
12 pack of medium cover plates*
EnviraZONE Zone panel
Equipment Interface Module for 2H/2C conventional systems
Equipment Interface Module for 2H/2C heat pump systems
Telephone Access Module
2-Channel Telephone Access Module
4-Channel Telephone Access Module
*Use to cover marks left by old thermostats.

Specifications

Temperature Ranges
• Heat: 40° to 90°F (4.5° to 32°C)
• Cool: 50° to 99°F (10° to 37°C)
Operating Ambient Temperature
• 32° to 120°F (0° to 48.9°C)
Shipping Temperature
• -20° to 120°F (-28.9° to 48.9°C)
System status
71
Software Revision Number (major revisions)
72
Software Revision Number (minor revisions)
73
Configuration Identification Number (major)
74
Configuration Identification Number (minor)
75
Production configuration date code (week)
76
Production configuration date code (year)
5
Operating Relative Humidity
• 5% to 90% (non-condensing)
Physical Dimensions
TH5220D
• 3-9/16" H x 5-13/16" W x 1-1/2" D
91 mm H x 147 mm W x 38 mm D
TH5110D
• 3-7/16" H x 4-1/2" W x 1-5/16" D
86 mm H x 114 mm W x 33 mm D
FocusPRO
TH5320
®
Part Number
50001137-001
50002883-001
50007297-001
50007298-001
W8835A1004
W8635A1006
W8635B1004
W8735B1003
W8735D1009
W8735D1017
69-2019EFS—02