Table 1.
TTA Unit Electrical Data
Model
Electrical
Number
Characteristics
TTA240F3
208-230/60/3
TTA240F4
460/60/3
TTA240FK
380/60/3
TTA240FW
575/60/3
TTA200FD
380-415/50/3
6

Electrical Data

Basic Unit Characteristics
Allowable
Minimum
Voltage
Circuit
Range
Ampacity
187-254
89.4
414-506
46.6
342-418
-
578-632
36.0
380-415
48.8
Compressor Motor
Maximum
Fuse
Amps
Size
Qty.
RLA
110
2
35.3
60
2
18.5
-
2
-
50
2
14.2
60
2
20.0
Outdoor Fan Motor
Amps
LRA
Qty.
HP
FLA
239.0
2
1
5.0
125.0
2
1
2.5
-
2
1
3.4
80.0
2
1
2.0
118.0
2
1
1.9
TTA-SVN03A-EN
LRA
14.4
5.8
7.8
5.1
5.8