User Function Commands

First disarm the system then enter
function you require from the following list:
[1] Time and Date
Enter 4 digits for 24 Hour System Time (HH-MM). Valid entries are 00-23 for the hour and 00-
59 for minutes. Enter 6 digits for the Month, Day and Year (MM-DD-YY)
[2] Auto-arm/Disarm Control
Pressing [2] while in the User Function menu will enable (3 beeps) or disable (one long
beep) the Auto-arm and Auto-Disarm feature, by partition. With this feature enabled, the
panel will automatically arm in the Away mode (Stay Away zones active) or disarm at the
same time each day. The auto-arm time is programmed with the [,][6][Master Code][3]
command. Auto-Disarm must be programmed by the system installer.
[3] Auto-arm Time
The system can be programmed to arm at a programmed time each day, per partition. Upon
entry of this section, enter 4 digits for the 24-hour Auto-arm time for each day of the week.
At the selected auto-arm time, the keypad buzzers will sound for a programmed amount of
time (programmable by the installer only) to warn that an auto-arm is in progress. The bell
can also be programmed to squawk once every 10 seconds during this warning period.
When the warning period is complete, the system will arm with no exit delay and in the Away
Mode.
Auto-arming can be cancelled or postponed by entering a valid access code only, during
the programmed warning period. Auto-arming will be attempted at the same time the next
day. When the auto-arming process is cancelled or postponed, the Auto-arm Cancellation
Reporting Code will be transmitted (if programmed).
If arming is inhibited by one of the following, the Auto-arm Cancellation transmission will be
communicated.
- AC / DC Inhibit Arm
- Latching System Tampers
- Zone Expander Supervisory Fault
[4] System Test
The system's Bell Output (2s), Keypad Lights and Communicator are tested. This test will
also measure the panel's standby battery.
[5] Enable DLS / Allow System Service
If enabled, the installer will be able to access Installer Programming by DLS. In case of DLS
access, this provides a window where rings will be detected by the panel. The DLS window
will remain open for 6 hrs, during which time the installer will be able to enter DLS an
unlimited number of times. After the 6-hr window has expired, Installer's Programming will
be unavailable again until the window is reopened.
[6] User Call-up
If enabled by the Installer, the panel will make 1 attempt to call the downloading computer.
The downloading computer must be waiting for the panel to call before downloading can be
performed.
[7] For Future Use
[8] User Walk Test (For Europe only)
This test allows the user to verify operation of system detectors.
NOTE: Fire zones, the 'F' key, and 2-wire smoke detectors are excluded from this test.
Violation of these zones will cause the system to exit the walk test then generate and
transmit alarm condition to the central station.
This display will be shown if a zone was open when you entered the
<>
bypassing command. The open zone will be represented by "O". If
O
you bypass the open zone, the "O" will be replaced by a "B".
To exit the bypassing mode and return to the Ready state, press the
[#] key.
[Master Code]. Then enter the number of the