Figure 1
A
B
B. Heater ON/OFF Switch
The Heater ON/OFF Switch supplies power to the heater fan and the
heater element.
C. Heater Thermostat Control
To adjust the temperature to your individual requirements, turn the
thermostat control clockwise all the way to turn on the heater. When
the room reached the desired temperature, turn the thermostat knob
counter clockwise until you hear a click. Leave in this position to
maintain the room temperature at this setting. For additional heat, turn
clockwise until you hear the click again and the heater will turn on.
To turn the heater off, switch the Heater ON/OFF Switch to the OFF
position.
!
NOTE: When the heater is switched ON, the heater fan will
operate. The heater element may or may not be on, depending on
the thermostat control setting (see "Heater Thermostat Control").
Resetting The Temperature Cutoff Switch
Should the heater overheat, an automatic cut out will turn the heater
off and it will not come back on without being reset. It can be reset by
switching the Main ON/OFF Switch to OFF and waiting five (5) minutes
before switching the unit back on.