Combiplus Installation Options - Viessmann VITODENSd 100-W Technical Data Manual

Wb1b series wall-mounted, gas-fired condensing boiler with optional on demand hot water combiplus kit 37 to 118 mbh & 10.8 to 34.5 kw
Table of Contents

Advertisement

Dimensions
Boiler minimum clearances
Recommended minimum boiler service clearances
Front

CombiPLUS installation options

Min. distance between the boiler and CombiPLUS with
Viessmann supplied 7" flex piping connection fittings.
Note: The maximum distance between
the boiler and the CombiPLUS
is restricted by the communication
cable to 36" (915 mm).
10
Side
Top
Back
Side
5
Recommended minimum boiler and CombiPLUS Kit
clearances to combustibles
Top
Front
0
0 AL,
CL
AL = Alcove
CL = Closet
1
*
Refer to the Installation Instructions
of the Vitodens Venting System
for details.
Note: The Vitodens 100-W boiler has passed the zero
inches vent clearance to combustibles testing
requirements dictated by the boiler latest
Harmonized Standard ANSI Z21.13. CSA 4.9.2007
and therefore is listed for zero clearance to
combustibles when vented with a single-wall special
venting system (AL-29-4C material) or UL/ULC-listed
CPVC/PP(s) gas vent material. The zero inches vent
clearance to combustibles for the Vitodens 100-W
boiler supercedes the clearance to combustibles
listing that appears on the special venting system
label.
Shown is the maximum distance between the boiler
and CombiPLUS using field supplied fittings and pipes.
Vitodens 100-W, WB1B Technical Data
Rear
Left
Right
0
0
0
Vent
pipe* 1
0

Hide quick links: