Viessmann VITODENS 100-W Operating Instructions & User's Information Manual

Wall-mounted, gas-fired condensing boiler with optional on demand hot water combiplus kit
Hide thumbs Also See for VITODENS 100-W:

Advertisement

Operating Instructions &
User's Information Manual
Vitodens 100-W
WB1B Series
Wall-Mounted, gas-fired condensing boiler
with optional on demand hot water CombiPLUS Kit
Heating input: 37 to 118 MBH
10.8 to 34.5 kW
VITODENS
5600 333 v1.2 09/2013
100-W
H
WARNING
If the information in this manual is not followed
exactly, a fire or explosion may result causing
property damage, personal injury or loss of life.
Do not store or use gasoline or other
fl ammable liquids in the vicinity of this
or any other appliance.
WHAT TO DO IF YOU SMELL GAS
Do not try to light any appliances.
Do not touch any electrical switches,
do not use any phone in your building.
Immediately call your gas supplier
from a neighbor's phone. Follow
the gas supplier's instructions.
If you cannot reach your gas supplier,
call the fi re department.
Installation and service must be
performed by a qualifi ed installer,
service agency or the gas supplier.
WARNING
Improper installation, adjustment, and/
or operation could cause carbon monoxide
poisoning resulting in injury or loss of life.
This product must be installed and serviced
by a professional service technician who is
experienced and qualified in hot water boiler
installation and gas combustion.
IMPORTANT
Read and save these instructions
for future reference
Please file in Service Binder
.

Advertisement

Table of Contents
loading

Summary of Contents for Viessmann VITODENS 100-W

  • Page 1: Operating Instructions

    Operating Instructions & User’s Information Manual Vitodens 100-W WB1B Series Wall-Mounted, gas-fired condensing boiler with optional on demand hot water CombiPLUS Kit Heating input: 37 to 118 MBH 10.8 to 34.5 kW VITODENS 100-W  WARNING If the information in this manual is not followed exactly, a fire or explosion may result causing property damage, personal injury or loss of life.
  • Page 2 Safety, Installation and Warranty Requirements Vitodens 100-W, WB1B Operating & User’s Information Safety, Installation and Warranty Requirements Please ensure that these instructions are read and understood before commencing installation. Failure to comply with the instructions listed below and details printed in this manual can cause product/property damage, severe personal injury, and/or loss of life.
  • Page 3: Table Of Contents

    Table of Contents Vitodens 100-W, WB1B Operating & User’s Information Page General Information About these Instructions..........4 Safety For your Safety............4 Operation...............4 Flue gas smell............4 Working on the equipment........4 Dangerous conditions..........4 Maintenance and cleaning........4 Technical Information..........4 Carbon monoxide............5 For safe operation...........5 Frozen water pipe hazard.........6...
  • Page 4: About These Instructions

    General Information/Safety Vitodens 100-W, WB1B Operating & User’s Information About these Instructions Take note of all symbols and notations intended to draw attention to potential hazards or important product information. These include “WARNING”, “CAUTION”, and “IMPORTANT”. See below. Warnings draw your attention to the presence of WARNING potential hazards or important product information.
  • Page 5: Carbon Monoxide

    Safety Vitodens 100-W, WB1B Operating & User’s Information For your Safety (continued) Carbon monoxide  WARNING The U.S. Consumer Product Safety Commission strongly recommends the installation of carbon As there are no user-serviceable parts on the boiler, monoxide detectors in buildings in which gas-burning burner or control, the end-user must not perform equipment is installed.
  • Page 6: Frozen Water Pipe Hazard

    Safety Vitodens 100-W, WB1B Operating & User’s Information For your Safety (continued) Frozen water pipe hazard If your home will be unattended for an extended period WARNING of time during cold weather, you should... Failure to protect against frozen pipes could result in...
  • Page 7: Installation Area Conditions

    Safety Vitodens 100-W, WB1B Operating & User’s Information For your Safety (continued) Installation area conditions WARNING WARNING If you notice fire coming from the appliance, call the fire department immediately! Do not attempt to Incorrect ambient conditions can lead to damage to extinguish the fire unless qualified to do so.
  • Page 8: Overview Of Controls And Indicators

    Start-up Vitodens 100-W, WB1B Operating & User’s Information Overview of Controls and Indicators Control and display elements Controls and indicators are located behind the hinged front cover. Flip up the front cover to access the controls. The control unit is preset at the factory for standard operation.
  • Page 9: Your Vitodens 100 Boiler

    Start-up/Operation Vitodens 100-W, WB1B Operating & User’s Information Your Vitodens 100 Boiler Please ask your heating contractor to check off the appropriate box (). Vitodens 100 without domestic hot water tank  The control unit activates and deactivates space heating and supplies rooms with heat.
  • Page 10: Heating System Operation

    Operation Vitodens 100-W, WB1B Operating & User’s Information Heating System Operation Switching ON Room dependent control: Outdoor temperature sensor not connected With no outdoor sensor installed, the “tr” dial will provide a constant temperature set-point for the boiler based on the dial position selected.
  • Page 11: Domestic Hot Water

    Operation Vitodens 100-W, WB1B Operating & User’s Information Domestic Hot Water Select the DHW temperature in accordance with your When in operation with a separate Domestic Hot Water requirements (e.g. for showering). (DHW) tank, the domestic hot water temperature is adjusted at the temperature control of the DHW tank.
  • Page 12: Comfort Function

    Operation Vitodens 100-W, WB1B Operating & User’s Information Comfort Function If the comfort function is switched ON (when used with the DHW CombiPLUS Kit only), the instantaneous water heater is kept up to temperature (standby). Hot water is therefore quickly available.
  • Page 13: Switching Off Vitodens With Frost Protection

    Operation Vitodens 100-W, WB1B Operating & User’s Information Switching OFF Vitodens with Frost Protection Switch OFF the equipment if you do not wish to use your heating system for a few days. Turn selector dial ”tr” to “0”. Boiler frost protection is active.
  • Page 14: Fault Diagnosis And Correction

    Operation Vitodens 100-W, WB1B Operating & User’s Information Fault Diagnosis and Correction Issue Cause Corrective Action Heating system does not start up Heating system switch turned to Turn switch to ON on control unit. OFF on control unit Set required heating water temperature Selector dial “tr”...
  • Page 15: Fault Messages On The Display

    Service Instructions for your Heating System Viessmann strongly recommends inspection/service of the boiler and the system by a licensed professional heating contractor once per year. Before the heating season begins, the boiler with its burner(s) and vent system should be serviced by a qualified heating contractor.
  • Page 16: How To Save Energy

    Information Vitodens 100-W, WB1B Operating & User’s Information How to Save Energy ..by heating the right way Apart from taking advantage of the benefits of a modern heating system, there is a lot you can do yourself to achieve additional fuel savings.
  • Page 17: Lighting And Operating Instructions

    Information Vitodens 100-W, WB1B Operating & User’s Information Lighting and Operating Instructions FOR YOUR SAFETY READ BEFORE OPERATING W A R N I N G: If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life.
  • Page 18 Vitodens 100-W, WB1B Operating & User’s Information...
  • Page 19 Vitodens 100-W, WB1B Operating & User’s Information...
  • Page 20 Vitodens 100-W, WB1B Operating & User’s Information Quick Reference °C °F +10 +50 +16 +61 +25 +77 +40 +104 +122 +140 +158 +176 +194 +100 +212 +110 +230...