Entrance Monitor Setting; Call Screen Setting - Aiphone GT SYSTEM Installation Manual

Apartment intercom system
Hide thumbs Also See for GT SYSTEM:
Table of Contents

Advertisement

5-18

Entrance monitor setting

Monitoring with the entrance station camera from a residential station can be set to be possible or not possible. The initial setting makes this not pos-
sible.
GT-DA-L/GT-DA: Switch this setting with 1 of SW2.
GT-DA-L/GT-DA
SW2
ON
1 2 3 4
Monitoring possible
Monitoring not possible
1
GT-DMV/GT-DM: Enter the program mode and select "MONITOR ENTRANCE".
MENU
VERIFY PROGRAM
SCROLL SPEED
MONITOR ENTRANCE
:ENTER
MONITOR ENTRANCE
OFF
ON
:ENTER
5-19

Call screen setting

Screen switching during a call can be set to "ZOOM", "WIDE", "ZOOM 3s >> WIDE", or "WIDE 3s >> ZOOM". The initial setting is "ZOOM".
GT-VA: Switch this setting with 3 and 4 of SW1.
GT-VA
SW1
ON
1 2 3 4
GT-DMV/GT-DM: Enter the program mode and select "CALL-IN DISPLAY".
MENU
CALL-IN DISPLAY
LIGHT OR CCTV
DISPLAY ROOM NO.
:ENTER
CALL-IN DISPLAY
ZOOM
WIDE
ZOOM 3s >> WIDE
:ENTER
Next menu item
ON
ON
ON
1 2 3 4
1 2 3 4
Next menu item
1 2 3 4