0311 A OI GT-2C-L/GT-2C 6(59,&( 0$18$/ GT-2H-L/GT-2H Apartment Intercom System Master Monitor Station/Sub Master Monitor Station GT-2C-L/GT-2C Master monitor station GT-2H-L/GT-2H Sub master monitor station OPERATION MANUAL...
(Negligence could result in injury to people or damage to property.) 1. For power supply, use Aiphone power supply model or model specified for use with system. If non-specified product is used, fire or malfunction could result. 2. Do not install the unit in any of the following locations. Fire, electric shock, or unit trouble could result.
1 NAMES Master monitor station (GT-2C-L/GT-2C) ...4 Sub master monitor station (GT-2H-L/GT-2H) ...4 2 VIEWING THE SCREEN (MASTER MONITOR STATION) ...5 3 OPERATING METHOD (MASTER MONITOR STATION) Turning off the screen display ...6 Setting the date and time ...6 4 RECEIVING CALLS Answering a call ...7...
NAMES Master monitor station (GT-2C-L/GT-2C) Color LCD video monitor Hearing aid T-mode compatibility symbol (GT-2C-L only) MENU button CALL button MONITOR button REC/PLAY button STATUS LED (orange) TONE OFF LED (orange) Microphone DOOR RELEASE button OPTION button Sub master monitor station (GT-2H-L/GT-2H)
VIEWING THE SCREEN (MASTER MONITOR STATION) CALLING ENTRANCE1 [Screen during calling] OPERATING METHOD (MASTER MONITOR STATION) To operate this unit, check the symbol and then press the appropriate operation button. This unit is not operated with touch-panel operation. Do not press on the LCD or subject it to high impact. The LCD glass could break which could result in an injury.
Turning off the screen display is displayed on the screen while video images are played. Press the [ MENU] button to turn off all items displayed on the screen (date, time, etc.) so that the entire picture is visible. Setting the date and time In the standby mode, press the [ MENU] button.
3 minutes when the hand- set is used. The unit emits an electromagnetic field. If a hearing aid with T-mode is brought too close to the unit, this may cause ear pain. (GT-2C-L/ GT-2H-L only) Log-data function for missed calls from security guard...
Door release Press the [ ] button while in communication with the entrance sta- tion. Light control Turning the entrance light on (when light is installed in common area) Press the [ GUARD] button once during entrance station calling, communication, or monitoring. Doctor call (master monitor station) When the specified residence is called using Doctor call (automatic en- try), the electric lock is automatically released without a door release op-...
If the other person presses the [ TALK] button, the STATUS LED lights up and communication between two people is possible. • Listening is possible with hearing aids with T-mode. (GT-2C-L/GT-2H-L only) Move the cursor to the security guard station to be called and press the GUARD] MENU] button.
MONITOR] button again to display the video image in order from entrance 1. Audio can heard at the same time. • Listening is possible with hearing aids with T-mode. (GT-2C-L/GT-2H-L only) NOTES: 1. If there is an operation such as a call, monitoring ends and the call operation begins.
OPERATION DURING COMMUNICATION AND MONITORING The unit used in the example pictures is a master monitor station. ZOOM/WIDE switching Press the [ ZOOM/WIDE] button when a picture is displayed. • Switching between zoom ⇔ wide occurs each time the button is pressed. Pan/tilt operation When a zoom picture is displayed, press the [S], [T], [W], or [X] button.
Night illumination At night, the illuminator LED lights up during an entrance station or indi- vidual door station call. Also, the LED can be made to light up during monitoring of a individual door station. When a call is made from an entrance station or individual door station If the call button of the entrance station or individual door station is pressed, the illuminator LED will light up.
RECORDING AND PLAYING (MASTER MONITOR STATION) Automatic recording If call is received from an entrance station or individual door station, re- cording starts automatically. During recording, the the screen. • Recording starts approximately 2 seconds after the CALL button of an entrance station or individual door station is pressed.
Playing recorded pictures If there are automatically recorded pictures, such as those taken while you were out, the STATUS LED blinks with a long interval during standby mode. Press the [ REC/PLAY] button in the standby mode to display the picture with the most recent date and time.
Saving recorded pictures 10 images can be saved from the recorded images (maximum of 40 images). Saved pictures are not overwritten. Display the picture that you want to save in the play-waiting screen. (Refer to section 8-3.) Press the [ MENU] button to display the save/erase selection screen.
ALARMS AND RELATED INFO. The unit used in the example pictures is a master monitor station. OPTION button Pressing the [ OPTION] button allows for operation of connected units to be performed such as turning lights on and off. Emergency alarm Press and lock the emergency alarm switch (or when there is a line - off trouble).
External calls When a separately-installed sensor is activated or the CALL button is pressed, the alarm sounds, and the warning screen displays on the monitor and blinks. • Only the alarm sounds at sub master monitor stations. 6(1625 $&7,9$7(' 5(6(7 PRESENCE SECURITY, ABSENCE SECURITY setting (master monitor station) Set the security settings for individual doors and windows.
Canceling security setting after arrival (master monitor station) When the ABSENCE SECURITY setting in 9-4 is set, if an individu- al door is opened, a screen will display and the alarm will sound. • At this time, operation other than an emergency alarm cannot be performed. Ex.: When a call is made from the entrance station, communication will not start.
CHANGING SETTINGS (MASTER MONITOR STATION) The screen may vary depending on the equipment being used. 10-1 Using the MENU In the standby mode, press the [ MENU] button. Press the [S] or [T] button to select "SETTINGS", and press the MENU] button.
10-3 CALL TONE switching Separate sounds can be selected for entrance stations, individual door sta- tions, and security guard stations from 5 sound types. After performing steps 1 and 2 in section 10-1, select "CALL TONE" in the "SETTINGS" screen and press the [ Select one from "ENTRANCE/DOOR/GUARD"...
10-5 External call sound time duration setting Select the external call sound time duration. The initial setting is "10 MIN.". After performing steps 1 and 2 in section 10-1, select "UTILITY" in the "SETTINGS" screen and press the [ Select "ALARM TIMER" in the "UTILITY" screen, and press the MENU] button.
10-7 Individual door night illumination setting Select whether the door station illuminator LED is enabled or disabled. The initial setting is "ENABLE". After performing steps 1 and 2 in section 10-1, select "DOOR" in the "SETTINGS" screen and press the [ Select "NIGHT ILLUMINATION"...
10-8 SECURITY PIN setting The security PIN to be used can be set when performing PRESENCE SECURITY and ABSENCE SECURITY setting. The initial setting is "DISABLE", when "ENABLE" is selected, the initial setting for the security PIN is [S], [X], [T], and [W]. After performing steps 1 and 2 in section 10-1, select "SECURITY"...
10-9 DEPARTURE TIMER, ARRIVAL TIMER setting With ABSENCE SECURITY, the delay time from when an action causing a warning response is detected to when a warning is actually sent can be set. The initial setting is "60 SEC.". DEPARTURE TIMER = Time from when ABSENCE SECURITY is set to when user leaves ARRIVAL TIMER = Time from when user arrives to when ABSENCE SECURITY is canceled...
Page 26
Aiphone warrants that its products have no material or workmanship defects under normal use conditions for two years after delivery to the end user. Aiphone will perform repair or replacement free of charge if the product is defective and the warranty applies to the defect. Aiphone reserves unto itself the sole right to make the final decision whether there is a defect in materials and/or workmanship and whether or not the product is under warranty.