NETWORK MANAGEMENT CONNECTIONS

The Total Access 3000 Chassis integrates onto the backplane several different management
ports to allow for remote management of the shelf, see
on the System Controller Unit (SCU) discussed in detail in the "Section 1, System Description"
in the Total Access 3000/3010 System Manual, P/N 61181001L1-1).
Depending on the selected system SCU, one of the following methods can be used to connect
to the system: NMA over TL1 on an X.25 network, SNMP over Ethernet, or Telnet from a
remote location.
Also, regardless of SCU selection, up to 32 shelves can be linked together on the RS-485 bus
for management of those shelves from a single management interface.
P 5
P A I R 4
64
20
20
P A I R 5
64
J33
NTWK MGMT
NTWK MGMT

Figure 10. Total Access 3000 Management Ports

Connecting the RS-485 Bus Between Shelves

Up to 32 shelves can be linked together for management from a single shelf designated as host
(the other shelves will be configured as clients). This feature allows conservation of valuable
external management ports within the CO, and provides local or remote management for up to
32 shelves from the craft interface on front of the host SCU, or from the remote management
port connections described in this section. To connect the RS-485 bus between shelves,
perform the following steps:
1. Determine and cut the length of wire necessary to reach from the RS-485 wire-wrap
header,
, in the first shelf in the chain to the RS-485 wire-wrap header,
P2
ond shelf. Remember to allow for stripping the ends of the wire, routing the wires out to
the right side of the shelf to the frame, and tying down in accordance with CO SOP.
61181001L1-5E
P 1 1
64
33
1
32
33
64
P 1 2
P A I R 3
32
10
Total Access
T
R
S
20
20
T1
Chassis
R1
S
LOOP
TEST
ACCESS
33
P9
64
1
32
64
33
P7
P A I R 6
32
1
-48 VDC PRI
-48 VDC SEC
P22
P3
A
B
A
B
A
B
A
B
NO
C
NC
NO
C
NC
1
-48 VDC
J30
RET
-48 VDC RET
ACO
RMT
AUX1
AUX2
AUX1
AUX2
J30
Figure
10. The management interface is
P A I R 2
64
33
1
33
32
P 8
1
P A I R 1
P24
EXTCLK
C-IN
1
+
S
P A I R 7
64
33
1
33
32
P 1 0
1
P A I R 8
EXTCLK
RS485
J32
ALARM OUTPUTS
P21
P1
P20
P19
P18
R21
+
S
+
S
+
+
S
A
B
A
B
NO
C
NC NO
C
NC NO
C
NC
NO
C
NC NO
C
NC NO
C
NC
P2
B - OUT
A - OUT
B IN
IN
OUT
E - NET
CRI-A
MAJ-A
MIN-A
CRI-A
MAJ-A
MIN-A
RS485
A
B
A
B
IN
OUT
Network Management Connections
ADMIN
J31
E D C B A
ADMIN
J31
E D C B A
E D C B A
P15
1
P14
1
J1
D
C
B
A
1
F2
F1
10
10
10
20
8
P23
20
DSX1
30
30
TEST
ACCESS
1
T
R
S
T1
40
R1
S
32
6
F4
F3
48
48
PC2A
94V-0
2298
1181004L1
CUSTOM
TELECOM
E190349
J32
P2
, in the sec-
P2
E - NET
23

Advertisement

Table of Contents
loading

This manual is also suitable for:

Total access 3000

Table of Contents