Factory Default Switch

If the factory default switch is pressed during bootup, the unit will stay in bootstrap mode. Since the unit
has no serial port, Telnet has been built into the boot code. The default IP address is 10.10.10.1.
The default switch must be pressed WHILE the power light is flashing green. Do not press
the default switch BEFORE the power light is flashing green, as this will cause boot to be
missed.
If the factory default switch is pressed and held for 5 seconds after boot, the
the NetVanta 340 (or the
10.10.10.1 and all access policies will be removed from that interface.
If the factory default switch is pressed for 30 seconds, a default configuration will overwrite your
existing configuration and reboot the unit.
61200422L1-34D
interface on the NetVanta 344 and NetVanta 347) will default to
VLAN 1