Worktop Cut-Out Km 414 / Km 417 - Miele KM 404 Installation Instructions Manual

Gas
Table of Contents

Advertisement

Dimensions 7 mm and 11 mm are the
space taken up by the frame of the
appliance on the worktop.
^ Make a cut-out for the hob in the
worktop.
Dimension "B" applies to a combination
of appliances and is shown on the
chart.
^ There must be a minimum safety
distance of 50 mm between the hob
and the back wall and 200 mm
distance from a side wall to the right
or left of the hob. (See "Warning and
safety instructions").
^ Seal the cut surfaces with a suitable
sealant to avoid swelling caused by
moisture.
The materials used must be heat
resistant.

Worktop cut-out KM 414 / KM 417

1 hob
Number
appliances
KM 414/417 + 1
KM 414/417 + 2
KM 414/417 + 3
KM 414/417 + 4
Important:
The maximum tolerance for the worktop
cut-out must not exceed ± 1 mm.
When building in several hobs a
spacer bar must be fitted between
each unit. See "Fitting spacer bars
and support brackets".
Narrow combiset appliances (288 mm
wide) can be installed to the left or right
hand side of the KM 414 / KM 417.
Worktop cut-out KM 414 / 417
Depth in mm
± 1 mm
500
Worktop cut-out KM 414 / 417 +
288 mm wide appliances
Depth
of
in mm
± 1 mm
500
500
500
500
Width (= Dim. B)
in mm
± 1 mm
552-560
Width
(= Dim. B)
in mm
± 1 mm
840
1 128
1 416
1 704