Reflected Temperature Compensation - Fluke Ti20 User Manual

Thermal imager
Hide thumbs Also See for Ti20:
Table of Contents

Advertisement

Reflected Temperature Compensation

Targets that have low emissivities will reflect energy from nearby objects. This additional
reflected energy is added to target's own emitted energy and may result in inaccurate
readings. In some situations objects near the target (machines, furnaces, or other heat
sources) have a temperature much higher than that of the target. In these situations it is
necessary to compensate for the reflected energy from those objects. The concept of
reflected temperature compensation is illustrated in Figure 2-5.
The Reflected Temperature Compensation (RTC) feature is disabled when
the emissivity is set to 1.00.
Note
Figure 2-5. Reflected Temperature Compensation
Reflected Temperature Compensation
Reflected Energy
Emitted Energy
Basic Operation
2
dag006f.eps
2-13