Installation; Installing The Fireplace Shell - Montigo M40DV-CR Installation Operation & Maintenance

Corner gas fireplace
Hide thumbs Also See for M40DV-CR:
Table of Contents

Advertisement

M40DV-CR/CL Corner Gas Fireplace

Installing The Fireplace Shell

The fireplace may be installed in any location that maintains clear-
ances to air conditioning ducts, electrical wiring and plumbing. Safety,
as well as efficiency of operation, must be considered when selecting
the fireplace location. Try to select a location that does not interfere
with room traffic, has adequate ventilation, and offers an accessible
pathway for Direct Vent installation.
The fireplace dimensions are shown below:
Front View
End View
Figure 1. Fireplace dimensions.
Clearances
The M40DV-CR/CL clearances to combustible materials are:
Top*
Rear
Closed Side
Floor
Mantle**
Flue Cover
* Clearance from the top of the fireplace to
a combustible ceiling within the fireplace
enclosure.
** Refer to page 12.
Page 4

Installation

Top View
8"
1½"
1½"
Combustible
6"
1/2"
WARNING!
When this appliance is installed directly on carpeting, tile or any
combustible material other than wood flooring, it must be installed
on a metal or wood panel extending the full width and depth of
the appliance.
Framing
Unprotected combustible walls which are perpendicular to the
fireplace opening, must not project beyond the shaded area shown in
Figure 20b.
For protection against freezing temperatures, it is recommended that
outer walls of the chase be insulated with a vapour barrier. This will
reduce the possibility of a cold-air convection current on the fireplace.
38"
Figure 2a. Framing dimensions.
Figure 2b. Flue Cover clearances to combustibles when installing
the unit in a top vent configuration.
41"
24"
40"
P/N XG0206