Wiring of the Forced Air Duct System Continued:
2 . Remove the cover over the electrical box at the right lower rear of
the fireplace . Run sheathed wire from the fireplace electrical box to
the switch box and from the switch box to the blower box . Install the
wire clamp in the unused knock-out hole in the fireplace electrical box
cover . Run the end of the sheathed wire through this wire clamp . In the
electrical box are a white wire and a red wire with clear caps on their
ends . Remove these caps and join the red wire and black wire with
the wire nuts provided . Also join the white wire from the fireplace with
the white wire from the sheathed wire using the wire nuts provided .
Fasten the ground wire from the sheathed wire to the green grounding
screw in the electrical box . When the fireplace gets up to temperature,
a heat activated switch will close and allow electricity to flow to the
red wire .
3 . At the switch box, cut the black sheathed wire, strip back the insula-
tion and join each end (with the wire nuts provided) to a lead from the
speed control . It does not matter which lead from the speed control is
fastened to which black wire . After making these connections, roll the
connectors and wire into the switch box . Two different colors of covers
and knobs come with the kit . Select the cover desired and fasten the
speed control and cover to the box with the screws supplied . Push
the desired knob onto the shaft of the speed control .
4 . Remove the four screws holding the blower to the blower box and lift
blower out of the blower box (see Figure 43) . Feed the sheathed wire
A through the wire clamp B . Remove the insulation from the sheathed
wire and the two wires coming from the blower motor . Join together
using the wire nuts provided the black wire from the motor and the
black sheathed wire . Also join the two white wires . Fasten the ground
wire to the green grounding screw inside the blower box . Reinstall
the blower in the blower box using the four screws .
Notes:
The speed of this forced air duct system blower can be controlled by the
speed control that is installed with it. The speed control also has an off
position. This blower is energized only when the fireplace is up to tem-
perature. It will also shut off automatically when the fireplace cools down.
To maximize warm air distribution, this forced air duct system can be
used in conjunction with the Whole Home Comfort System described
in this manual.
Grill Installation:
The Grill that covers the blower box is secured
with the two white-headed screws provided . When the blower box is
mounted in a 2"x4" framed wall the box will extend past the sheetrocked
wall into the room . In these installations the Grill spacer should be used
(see Figure 42) .
Figure 42
C
Figure 43
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
Grill Spacer
Grill
B
A
31