Format Command Execution Time (Minutes); General Performance Characteristics; Start/Stop Time - Seagate Cheetah 15K.6 SAS Product Manual

Table of Contents

Advertisement

4.2.2

Format command execution time (minutes)

Maximum (with verify)
Maximum (without verify)
Execution time measured from receipt of the last byte of the Command Descriptor Block (CDB) to the request
for a Status Byte Transfer to the Initiator (excluding connect/disconnect).
4.2.3

General performance characteristics

Sustainable disk transfer rate*:
Minimum
Maximum
SAS Interface maximum instantaneous transfer rate
Logical block sizes
Default is 512-byte data blocks
Sector sizes variable to 512, 520, and 528 kbytes.
Read/write consecutive sectors on a track
Flaw reallocation performance impact (for flaws reallocated at format time using
the spare sectors per sparing zone reallocation scheme.)
Average rotational latency
*Assumes system ability to support the rates listed and no cable loss.
1 MB/sec = 1,000,000 bytes/sec
4.3

Start/stop time

The drive accepts the commands listed in the SAS Interface Manual less than 3 seconds after DC power has
been applied.
If the drive receives a NOTIFY (ENABLE SPINUP) primitive through either port and has not received a START
STOP UNIT command with the START bit equal to 0, the drive becomes ready for normal operations within 20
seconds (excluding the error recovery procedure).
If the drive receives a START STOP UNIT command with the START bit equal to 0 before receiving a NOTIFY
(ENABLE SPINUP) primitive, the drive waits for a START STOP UNIT command with the START bit equal to 1.
After receiving a START STOP UNIT command with the START bit equal to 1, the drive waits for a NOTIFY
(ENABLE SPINUP) primitive. After receiving a NOTIFY (ENABLE SPINUP) primitive through either port, the
drive becomes ready for normal operations within 20 seconds (excluding the error recovery procedure).
If the drive receives a START STOP UNIT command with the START bit and IMMED bit equal to 1 and does
not receive a NOTIFY (ENABLE SPINUP) primitive within 5 seconds, the drive fails the START STOP UNIT
command.
12
ST3450856SS
ST3300656SS
176
144
88
72
ST3146356SS
100
50
112 Mbytes/sec (typical)
171 Mbytes/sec (typical)
300 Mbytes/sec* per port
Yes
Negligible
2.0 msec
Cheetah 15K.6 SAS Product Manual, Rev. A