Roland DP990F Implementation page 3

Midi implementation
Hide thumbs Also See for DP990F:
Table of Contents

Advertisement

○Portamento control (Controller number 84)
Status
2nd byte
3rd byte
BnH
54H
kkH
n = MIDI channel number:
0H-FH (ch.1-ch.16)
kk = source note number:
00H-7FH (0-127)
* A Note-on received immediately after a Portamento Control message will
change continuously in pitch, starting from the pitch of the Source Note
Number.
* If a voice is already sounding for a note number identical to the Source Note
Number, this voice will continue sounding (i.e., legato) and will, when the next
Note-on is received, smoothly change to the pitch of that Note-on.
* The rate of the pitch change caused by Portamento Control is determined by
the Portamento Time value.
Example 1.
On MIDI
Description
90 3C 40
Note on C4
B0 54 3C
Portamento
Control from C4
90 40 40
Note on E4
80 3C 40
Note off C4
80 40 40
Note off E4
Example 2.
On MIDI
Description
B0 54 3C
Portamento
Control from C4
90 40 40
Note on E4
80 40 40
Note off E4
○Effect 1 (Reverb Send Level) (Controller number 91)
Status
2nd bytes
3rd byte
BnH
5BH
vvH
n = MIDI channel number: 0H-FH (ch.1-ch.16)
vv = Control value :
00H-7FH (0-127), Initial Value = 28H (40)
* This message adjusts the Reverb Send Level of each Part.
○Effect 3 (Chorus Send Level) (Controller number 93)
Status
2nd byte
3rd byte
BnH
5DH
vvH
n = MIDI channel number: 0H-FH (ch.1-ch.16)
vv = Control value:
00H-7FH (0-127), Initial Value = 00H (0)
* This message adjusts the Chorus Send Level of each Part.
○NRPN MSB/LSB (Controller number 98, 99)
Status
2nd byte
3rd byte
BnH
63H
mmH
BnH
62H
llH
n = MIDI channel number:0H-FH (ch.1-ch.16)
mm = upper byte (MSB) of the parameter number specified by NRPN
ll = lower byte (LSB) of the parameter number specified by NRPN
* Rx.NRPN is set to OFF by power-on reset or by receiving "GM1 System On"
or "GM2 System On," and NRPN message will be ignored. NRPN message will
be received when Rx.NRPN = ON, or by receiving "GS RESET."
* The value set by NRPN will not be reset even if Program Change or Reset All
Controllers is received.
**NRPN**
The NRPN (Non Registered Parameter Number) message allows an extended
range of control changes to be used.
To use these messages, you must first use NRPN MSB and NRPN LSB
Result
C4 on
no change (C4 voice still sounding)
glide from C4 to E4
no change
E4 off
Result
no change
E4 is played with glide from C4 to E4
E4 off
messages to specify the parameter to be controlled, and then use Data Entry
messages to specify the value of the specified parameter. Once an NRPN
parameter has been specified, all Data Entry messages received on that
channel will modify the value of that parameter. To prevent accidents, it is
recommended that you set RPN Null (RPN Number = 7FH/7FH) when you
have finished setting the value of the desired parameter. Refer to Section 4.
Supplementary material "Examples of actual MIDI messages" <Example 4>.
On the GS devices, Data entry LSB (llH) of NRPN is ignored, so it is no problem
to send Data entry MSB (mmH) only (without Data entry LSB).
On this instrument, NRPN can be used to modify the following parameters.
NRPN
Data entry
MSB LSB
MSB
Description
01H 08H
mmH
Vibrato Rate (relative change)
mm: 0EH-40H-72H (-50 - 0 - +50)
01H 09H
mmH
Vibrato Depth (relative change)
mm: 0EH-40H-72H (-50 - 0 - +50)
01H 0AH
mmH
Vibrato Delay (relative change)
mm: 0EH-40H-72H (-50 - 0 - +50)
01H 20H
mmH
TVF Cutoff Frequency (relative change)
mm: 0EH-40H-72H (-50 - 0 - +50)
01H 21H
mmH
TVF Resonance (relative change)
mm: 0EH-40H-72H (-50 - 0 - +50)
01H 63H
mmH
TVF&TVA Envelope Attack Time (relative change)
mm: 0EH-40H-72H (-50 - 0 - +50)
01H 64H
mmH
TVF&TVA Envelope Decay Time (relative change)
mm: 0EH-40H-72H (-50 - 0 - +50)
01H 66H
mmH
TVF&TVA Envelope Release Time (relative change)
mm: 0EH-40H-72H (i-50 - 0 - +50)
18H rrH
mmH
Drum Instrument Pitch Coarse (relative change)
r: key number of drum instrument
mm: 00H-40H-7FH (-63 - 0 - +63 semitone)
1AH rrH
mmH
Drum Instrument TVA Level (absolute change)
rr: key number of drum instrument
mm: 00H-7FH (zero-maximum)
1CH rrH
mmH
Drum Instrument Panpot (absolute change)
rr: key number of drum instrument
mm: 00H, 01H-40H-7FH
(Random, Left-Center-Right)
1DH rrH
mmH
Drum Instrument Reverb Send Level
(absolute change)
rr: key number of drum instrument
mm: 01H-7FH (zero-maximum)
1EH rrH
mmH
Drum Instrument Chorus Send Level
(absolute change)
rr: key number of drum instrument
mm: 01H-7FH (zero-maximum)
* Parameters marked "relative change" will change relatively to the preset
value(40H). Even among different GS devices, "relative change" parameters
may sometimes differ in the way the sound changes or in the range of change.
* Parameters marked "absolute change" will be set to the absolute value of the
parameter, regardless of the preset value.
* Data entry LSB (llH) is ignored.
○RPN MSB/LSB (Controller number 100, 101)
Status
2nd byte
BnH
65H
BnH
64H
n = MIDI channel number: 0H-FH (ch.1-ch.16)
mm = upper byte (MSB) of parameter number specified by RPN
ll = lower byte (LSB) of parameter number specified by RPN
* Not received when Rx.RPN = OFF. (Initial value is ON)
*The value specified by RPN will not be reset even by messages such as
Program Change or Reset All Controller.
**RPN**
The RPN (Registered Parameter Number) messages are expanded control
changes, and each function of an RPN is described by the MIDI Standard.
To use these messages, you must first use RPN MSB and RPN LSB messages
3
3rd byte
mmH
llH