Roberts Gorden Caribe CGTH-30 Use And Care Manual page 18

Gas-fired, low-intensity infrared heaters for residential garages and light industrial/commercial applications
Hide thumbs Also See for Caribe CGTH-30:
Table of Contents

Advertisement

CGTH U
C
M
SE AND
ARE
ANUAL
Clearance to each
side of center line
H
extended above
meter/regulator
assembly
Clearance to
I
service regulator
vent outlet
Clearance to non-
mechanical air
supply inletto
J
building or the
combustion air inlet
to any other
appliance
Clearance to
K
mechanical air sup-
ply inlet
Clearance above
paved sidewalks or
L
paved driveway
located on private
property
Clearance under
M
veranda, porch,
deck, or balcony
1
In accordance with the current CSA B149.1, Natural Gas and Propane Installation Code
In accordance with the current ANSI Z223.1/NFPA 54, National Fuel Gas Code
2
+
A vent shall not terminate directly above a sidewalk or paved driveway that is located between two single
family dwellings and serves both dwellings.
** Permitted only if veranda, porch, deck, or balcony is fully open on a minimum of two sides beneath the
floor.
*
For clearances not specified in ANSI Z223.1/NFPA 54 or CSA B149.1, one of the following shall be
indicated:
a) A minimum clearance value determined by testing in accordance with section 4.7.3, 6.5.5, 8.5.5; or;
b) A reference to the following footnote:
"Clearance in accordance with local installation codes and the requirements of the gas supplier."
12
3' (91 cm) within a height 15' (4.5 m) above
the meter/regulator assembly
3' (91 cm)
12" (30 cm)
6' (1.83 m)
7' (2.13 m)
12' (30 cm)**
3' (91 cm) above if within 10' (3 m)
+
*
*
9" (23 cm)
horizontally
+
7' (2.13 m)
12" (30 cm)**

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Caribe cgth-40Caribe cgth-50

Table of Contents