q
Changing Presser Foot
• To remove
Turn the handwheel toward you to raise the
needle to its highest position. Press the lever
q on the back of the foot holder. The presser
foot will drop off.
w
• To attach
Place the presser foot so the pin e on the foot
e
lines just under the groove w of the foot
holder. Lower the foot holder to lock the foot in
place.

Bobbin Winding

• Removing bobbin case
Remove the extension table from the machine
by pulling it to the left. Open the shuttle cover
q by pulling down the embossed part on the
left of the cover.
Raise the needle to its highest position by
rotating the handwheel toward you.
q
To remove the bobbin case w from the shuttle,
pull open the latch of the bobbin case. Pull the
bobbin case w straight out of the shuttle.
2
14
q Lever
w Groove
e Pin
q Shuttle cover
w Bobbin case