Rinnai ENERGYSAVER EX17C Operation And Installation Manual

Energysaver gas direct vent wall furnace
Hide thumbs Also See for ENERGYSAVER EX17C:
Table of Contents

Advertisement

Available languages

Available languages

Owner's Operation and Installation Manual for the
EX17C (RHFE-434FTA)
EX22C (RHFE-559FTA)
Gas Direct Vent Wall Furnace
WARNING: If the information in these instructions is not
followed exactly, a fire or explosion may result causing
property damage, personal injury or loss of life.
- Do not store or use gasoline or other flammable vapors and
liquids in the vicinity of this or any other appliance.
- WHAT TO DO IF YOU SMELL GAS
Do not try to light any appliance.
Do not touch any electrical switch; do not use any phone in
your building.
Immediately call your gas supplier from a neighbor's phone.
Follow the gas supplier's instructions.
If you cannot reach your gas supplier, call the fire department.
- Installation and service must be performed by a qualified
installer, service agency or the gas supplier.
INSTALLER: Leave this manual with the appliance.
CONSUMER: Retain this manual for future reference.
Register your product at www.rinnairegistration.com
or call 1-866-RINNAI1 (746-6241)
Energysaver
®
Table of Contents .......................... 2
Specifications ................................ 4
Operating Instructions ................... 6
Installation Instructions ............... 15
Consumer Support ...................... 44
French Version ............................ 46

Advertisement

Table of Contents
loading

Summary of Contents for Rinnai ENERGYSAVER EX17C

  • Page 1: Table Of Contents

    Owner’s Operation and Installation Manual for the EX17C (RHFE-434FTA) EX22C (RHFE-559FTA) Energysaver Gas Direct Vent Wall Furnace WARNING: If the information in these instructions is not followed exactly, a fire or explosion may result causing property damage, personal injury or loss of life.
  • Page 2: Table Of Contents

    Operating Instructions ... 30 Cut-Away Diagram ... 31 Wiring Diagram ... 32 Ladder Diagram ... 33 Parts List ... 34-43 Consumer Support Warranty Information ... 44 Limited Warranty ... 44, 45 French Version ... 46-80 Rinnai Corporation EX17C / EX22C Manual...
  • Page 3: Consumer Safety Information

    • Do not sit on the heater. • Do not place containers of liquid on top of the heater. Water spillage can cause extensive damage to the appliance and may result in electric shock. Rinnai Corporation EX17C / EX22C Manual...
  • Page 4: Specifications

    33-38 dB AFUE Rating Natural Gas: 81% Rinnai is continually updating and improving products. Therefore, specifications are subject to change without prior notice. The efficiency rating of this appliance is a product thermal efficiency rating determined under continuous operating conditions and was determined independently of any installed system.
  • Page 5: Features

    FOT-153 15 3/4 - 23 5/8 in (400 - 600 mm) FOT-154 23 5/8 - 31 1/2 in (600 - 800 mm) Rinnai Corporation EX17C / EX22C Manual Propane Gas 8.0 in (203 mm) W.C. 13.0 in (330 mm) W.C.
  • Page 6: Operating Instructions

    GAS CONNECTION 1/2” MALE NPT POWER CORD PLUG 120V AC, 60 Hz Operating Instructions ROOM TEMPERATURE SENSOR/THERMISTOR Rinnai Corporation EX17C / EX22C Manual CONTROL PANEL RATING PLATE MODEL NUMBER, SERIAL NUMBER, GAS TYPE, ETC. ENGLISH IS ON THE RIGHT; FRENCH IS...
  • Page 7: Control Panel

    Deactivating the lock releases the control buttons. comfortable heating effect and to reach the temperature setting quickly. Occasionally, the room temperature may briefly exceed the temperature setting due to the layout of the room or heating area. Rinnai Corporation EX17C / EX22C Manual...
  • Page 8: Setting The Clock

    Timer button. The heater will operate from the start to end times you have entered for that Timer. It will operate at the temperature setting that has been set for the heater. The timer can be set while the heater is operating. Rinnai Corporation EX17C / EX22C Manual...
  • Page 9: Override Function

    2 ºF, effectively saving energy. The room temperature setting will drop up to a total of 4 ºF. The Economy Mode will not operate if the heater is under capacity for the room size. Rinnai Corporation EX17C / EX22C Manual 2°F reduction 2°F reduction 30 min...
  • Page 10: Set Back

    Do not bend repeatedly (no more than 5 times) or else the louver will break. The horizontal louvers (which determines the vertical air flow direction) are fixed and cannot be adjusted. Rinnai Corporation EX17C / EX22C Manual Do not adjust the air flow louvers while warm air is flowing.
  • Page 11: Care And Maintenance

    Maintenance All maintenance and service are to be performed by a qualified service technician, preferably one who has attended Rinnai service training classes on the Direct Vent products. The appliance should be inspected annually by a qualified service technician. More frequent cleaning may be required due to excessive lint from carpeting, bedding material, etc.
  • Page 12: Before Making A Service Call

    This is to remove the residual heat from the heat exchanger. The fan will stop when the heater cools down. High efficiency appliances tend to discharge water vapor on cold days. This is normal. Check whether filters are blocked. Dirty filters will cause the heater to overheat. Rinnai Corporation EX17C / EX22C Manual...
  • Page 13: Fault Codes

    You may be able to clear the fault code by turning the heater off and then on again. If the fault code remains or returns on the next operation, contact Rinnai or your nearest service agent and arrange for a service call.
  • Page 14: Restart Function

    Air filter blocked Gas Escape Child Lock Set Gas turned off at meter, tank, or valve. ON Timer is set Rinnai Corporation EX17C / EX22C Manual Remedy Plug In Push On/Off button to attempt restart after power is restored. Purge air...
  • Page 15: Installation Instructions

    • Rinnai suggests that a dedicated electrical circuit with a 120V AC, 60 Hz, 10 amp power source be used.
  • Page 16: Gas Connection

    Do not conceal manual cut-off valve behind back spacer. 2 in (50 mm) 40 in (1 m) Rinnai Corporation EX17C / EX22C Manual Manual gas shut-off valve Zero - See Notice Zero 2 in...
  • Page 17: Dimensions

    29.9 in (760 mm) 10.1 in 257 mm 6.8 in 3.3 in 172 mm 85 mm A full size template is provided on the NOTICE cardboard packaging. DO NOT DISCARD until installation is completed. Rinnai Corporation EX17C / EX22C Manual...
  • Page 18: Flue Terminal Clearances

    Flue Terminal Clearances Rinnai Corporation EX17C / EX22C Manual...
  • Page 19 7 feet (2.13 m) 1 12 inches (30 cm) to non- flammables 2 24 inches (60 cm) to flammables 2 Rinnai Corporation EX17C / EX22C Manual US Installations 12 inches (30 cm) 6 inches (15 cm) for appliances < 10,000 BTUh;...
  • Page 20: Installation Parts

    Plastic tie (L=250mm) Screw (M4) Wood Screw (M4.8× 32) Spacer Bracket * This plastic tie should be located here Rinnai Corporation EX17C / EX22C Manual (‘A’ Flue units only) (For weatherboard installations) For Flue Manifold Wall Bracket Screws...
  • Page 21: Drilling Flue Hole

    The shaded area shows where the flue manifold can be located. Configuration viewed from behind the appliance. Flue Hole NOTICE Rinnai Corporation EX17C / EX22C Manual Use a template (included) to determine allowable location of the flue hole.
  • Page 22: Flue Manifold Installation

    • This appliance can only be used with one of the five types of Rinnai flue kits. The flue kits and their dimensions are listed on the previous page. • Refer to the Flue Terminal Clearances section.
  • Page 23 Attach the inside connection with 3 screws. The inner connection can still be turned to install the screws. Terminal seal Locking tie Locking ties 3 screws Rinnai Corporation EX17C / EX22C Manual Terminal Sleeve...
  • Page 24: Extension Kit Installation

    (6) Vent extensions must not be concealed per NFPA 54 and must be accessible allowing inspection and repair. Decorative covers are available from Rinnai. These figures show the 3 possible ways that the extension exhaust line and air intake hose may be directed away from the appliance.
  • Page 25 The hose can be cut to the required length. Deburr all rough edges. Do not cut the hose attached to the appliance. Support the air intake hose with pipe clamps. Rinnai Corporation EX17C / EX22C Manual Exhaust pipe Exhaust pipe Air intake hose...
  • Page 26 EXHAUST PIPE(NON ADJUSTABLE) ⑥ HOSE JOINT ⑪ NUT FOT-201 FOT-219 FOT-220 FOT-221 FOT-158 FOT-190 2 sets Rinnai Corporation EX17C / EX22C Manual AIR INTAKE HOSE ⑦ PIPE STOPPER A ⑧ PIPE STOPPER B ⑬ SCREW B ⑫ SCREW A 3 sets...
  • Page 27: Connecting The Appliance

    6. Install the wall bracket with two screws. Attach the heater to the wall bracket with 2 screws. Flue Manifold Pipe stopper Elbow Top Spacer Rinnai Corporation EX17C / EX22C Manual Hook Manifold Pipe stopper Fit Clip Slide Sock Spacer bracket...
  • Page 28: Adjust Gas Pressure Settings

    0.54 in 0.60 in (14 mm) (15 mm) 2.0 in 1.8 in (52 mm) (47 mm) Rinnai Corporation EX17C / EX22C Manual Propane Gas L1 / L5 L2 / L6 L3 / L7 0-2000 ft 2001-5200 ft 5201-7700 ft 0-610 m...
  • Page 29: Normal Operating Sequence

    Yellow flames or orange color Final Assembly 1. Install the front panel and bottom cover. 2. If doing a gas type conversion, place the new conversion plate (label) on the front cover. Rinnai Corporation EX17C / EX22C Manual Flame Rod Flame Rod...
  • Page 30: Operating Instructions

    NOTE: The fan will continue to operate until the to the Rinnai Corporation EX17C / EX22C Manual appliance is cool. Do not turn the appliance off by unplugging it from the wall. Keep burner and control compartment clean.
  • Page 31: Cut-Away Diagram

    Cut-Away Diagram Rinnai Corporation EX17C / EX22C Manual...
  • Page 32: Wiring Diagram

    OVER HEAT THERMISTOR OHS1, 2 OVER HEAT SWITCH 1, 2 CONVECTION FAN MOTOR SPARKER SV1, 2 MAIN SOLENOID VALVE 1, 2 COMBUSTION FAN MOTOR PRESSURE SENSOR Rinnai Corporation EX17C / EX22C Manual CODE COLOR black blue green gr/y green/yellow white...
  • Page 33: Ladder Diagram

    Ladder Diagram Rinnai Corporation EX17C / EX22C Manual...
  • Page 34: Parts List

    Parts List For replacement parts call Rinnai at 1-800-621-9419. Rinnai Corporation EX17C / EX22C Manual...
  • Page 35 Parts List Rinnai Corporation EX17C / EX22C Manual...
  • Page 36 Parts List Rinnai Corporation EX17C / EX22C Manual...
  • Page 37 Parts List Rinnai Corporation EX17C / EX22C Manual...
  • Page 38 Parts List Rinnai Corporation EX17C / EX22C Manual...
  • Page 39 Parts List Rinnai Corporation EX17C / EX22C Manual...
  • Page 40 Parts List (Liste de pieces) Pour les pièces de rechange appelez Rinnai au 1-800-621-9419. Name Rear Panel B Frame R Frame L Frame Center Bottom Plate Support Humidifier Tray Fixing Plate support - bac d’humidificateur Bottom Plate Upper Partition Top Plate Supporter H...
  • Page 41 Rinnai Corporation EX17C / EX22C Manual Part Number (Numéro de la EX22C-W Pièce) EX22C (white) RHF300-152...
  • Page 42 Rinnai Corporation EX17C / EX22C Manual Part Number (Numéro de la EX22C-W Pièce) EX22C (white) 208000018 208000013...
  • Page 43 étiquette de corde d'alimentation d'énergie étiquette d'attention étiquette d'attention manuel For converting to NG (Pour la conversion NG) (Pour la conversion LPG) 204000035 204000036 Rinnai Corporation EX17C / EX22C Manual Part Number (Numéro de la EX22C-W Pièce) EX22C (white) ES-01171 205000053 205000037...
  • Page 44: Consumer Support

    What will Rinnai do? Rinnai will repair or replace the covered product or any part or component that is defective in materials or workmanship as set forth. Rinnai will pay reasonable labor charges associated with the repair or replacement of any such part or component. All repair parts must be genuine Rinnai parts.
  • Page 45: Limited Warranty

    Replacement of the product may be authorized by Rinnai only. Rinnai does not authorize any person or company to assume for it any obligation or liability in connection with the replacement of the product. If Rinnai determines that repair of a product is not possible, Rinnai will replace the product with a comparable product at Rinnai’s discretion.
  • Page 46: French Version

    éviter tout dommage matériel, toute blessure ou la mort. Rinnai Corporation EX17C / EX22C Manual ® Table des matières ... 47 Sécurité du consommateur ..48 Spécifications ...
  • Page 47 Instructions de mise en œuvre ... 75 Schéma en coupe ... 76 Schéma de câblage ... 77 Diagramme logique ... 78 Liste de pièces ... 34-43 Service à la clientèle Informations de garantie ... 79 Garantie limitée ... 79, 80 Rinnai Corporation EX17C / EX22C Manual...
  • Page 48: Sécurité Du Consommateur

    • Ne pas s'asseoir sur le chauffage. • Ne placez pas de conteneurs de liquide sur le dessus du chauffage. Déversement d'eau peut causer des dommages considérables à l'appliance et peut entraîner des chocs électriques. Rinnai Corporation EX17C / EX22C Manual...
  • Page 49: Spécifications

    Rendement Gaz naturel Rinnai poursuit constamment la mise à niveau et l’amélioration de ses produits. De ce fait ces spécifications sont sujet- tes à changement sans préavis. Le rendement énergétique de cet appareil mesure l’efficacité thermique du produit en utilisation continue, il a été...
  • Page 50: Caractéristiques

    FOT-153 15 3/4 - 23 5/8 in (400 - 600 mm) FOT-154 23 5/8 - 31 1/2 in (600 - 800 mm) Rinnai Corporation EX17C / EX22C Manual Gaz propane 8.0 in (203 mm) W.C. 13.0 in (330 mm) W.C.
  • Page 51: Instructions D'utilisation

    CÔTÉS ET TIRER VERS VOUS CONNEXIONS DE GAZ 1/2 mâle NPT FICHE PLUG 120V AC, 60 Hz Instructions d’utilisation THERMISTANCE Rinnai Corporation EX17C / EX22C Manual AFFICHAGE PLAQUE SIGNALÉTIQUE RÉFÉRENCE DE MODÈLE, N° DE SÉRIE, TYPE DE GAZ, ETC. FILTRE À AIR...
  • Page 52: Panneau De Commandes

    La désactivation du verrouillage libère les boutons de commande. De temps en temps la température ambiante peut dépasser brièvement la consigne du fait de la disposition de la pièce ou de la zone chauffée. Rinnai Corporation EX17C / EX22C Manual...
  • Page 53: Mise À L'heure

    Timer choisi. Le chauffage va fonctionner entre l'heure de départ et l'heure de fin que vous avez déterminées pour cette minuterie. Il chauffera à la température de consigne qui a été définie pour l'appareil. Rinnai Corporation EX17C / EX22C Manual...
  • Page 54: Fonction De Surpassement

    Le réglage de la température de la pièce sera au goutte-à- goutte u p pour un total de 4 ºF. Ce mode ne peut pas être activé si le chauffage est sous- dimensionné par rapport à la taille de la pièce. Rinnai Corporation EX17C / EX22C Manual...
  • Page 55: Programmation De Température Minimale

    Le registre horizontal (qui détermine la direction en hauteur du flux d'air) est fixe et ne peut pas se régler Rinnai Corporation EX17C / EX22C Manual N'ajustez pas les registres de flux d'air pendant que de l'air chaud est envoyé.
  • Page 56: Soins Et Entretien

    Entretien Toute intervention d’entretien et dépannage doit être effectuée par un technicien de service qualifié, qui de préférence a suivi des cours de service chez Rinnai sur ses produits à ventilation directe. L’appareil doit être inspecté annuellement par un technicien de service qualifié.
  • Page 57: Avant D'appeler Pour De L'aide

    High efficiency appliances tend to discharge water vapor on cold days. This C’est un phénomène normal. is normal. Regardez si les filtres sont saturés. Cela peut causer une surchauffe de l’appareil. Check whether filters are blocked. Dirty filters will cause the heater to overheat. Rinnai Corporation EX17C / EX22C Manual...
  • Page 58: Codes De Défauts

    Si le code de défaut est resté présent ou revient à la remise en route, contactez Rinnai ou votre agent de service le plus proche pour planifier une intervention. DÉFAUT Panne d’allumage...
  • Page 59: Fonction De Redémarrage

    ● ● ● ● ● ● ● ● ● ● Rinnai Corporation EX17C / EX22C Manual Remède Brancher l’appareil Mettre à l’arrêt et remettre en marche au retour du sec- teur Purger l’air (installateur) ● Demande d’intervention Demande d’intervention ●...
  • Page 60: Instructions D'installation

    Cet appareil ne doit pas être relié à une cheminée d’évacuation de fumées desservant aussi un autre appareil de chauffage à combustion. • Rinnai suggère d’utiliser comme source d’alimentation secteur un circuit dédié à l’appareil (120 V CA, 60 Hz, 10 A). •...
  • Page 61: Connexion Du Gaz

    Ne la placez pas dans l’intervalle derrière l’appareil. 2 in (50 mm) 40 in (1 m) Rinnai Corporation EX17C / EX22C Manual Manuel de gaz robinet d'arrêt. zéro - voir la notification zéro 2 in...
  • Page 62: Dégagements En Sortie De Cheminée

    Dégagements en sortie de cheminée Rinnai Corporation EX17C / EX22C Manual...
  • Page 63 7 pi (2,13 m) 1 12 po (30 cm) jusqu’aux matériaux non-inflammables 2 24 po (61 cm) jusqu’aux matériaux inflammables 2 Rinnai Corporation EX17C / EX22C Manual Installations USA 12 po (30 cm) 6 po (15 cm) pour des appareils < 10 000 BTU/h 9 po (23 cm) pour des appareils >...
  • Page 64: Dimensions

    10.1 in 257 mm 6.8 in 3.3 in 172 mm 85 mm Un modèle de taille complète est fourni AVIS sur l'emballage en carton. NE JETEZ pas jusqu'à ce que l'installa- tion est terminée. Rinnai Corporation EX17C / EX22C Manual...
  • Page 65: Pièces D'installation

    Vis (bois) Wood Screws (M4.8× 32) Support Spacer Bracket espaceur Rinnai Corporation EX17C / EX22C Manual Joint caoutchouc de rechange (‘A’ Flue units only) (appareils à ventilation « A » uniquement) (For weatherboard installations) (pour installations avec parement bois) For Flue Manifold (pour collecteur de fumée)
  • Page 66: Perçage Du Trou De Cheminée

    La zone hachurée montre où le collecteur de fumée peut être situé. Configuration viewed from behind the appliance. Flue Hole Trou de cheminée AVIS Rinnai Corporation EX17C / EX22C Manual Utiliser un modèle (inclus) pour déterminer l'emplacement autorisé du trou carneau.
  • Page 67: Installation Du Collecteur De Fumée

    • L’appareil ne peut être utilisé qu’avec l’un des cinq types de kits de collecteurs de fumée de Rinnai. Ces kits et leurs dimensions sont listés dans la section des spécifi- cations. •...
  • Page 68 Fixez la connexion intérieure avec trois vis. Elle peut toujours être tournée pour placer ces vis. Joint de terminaison Attache de blocage Attaches de blocage 3 vis Rinnai Corporation EX17C / EX22C Manual Terminaison Manchon...
  • Page 69: Installation Du Kit D'extension

    (6) Les extensions de ventilation ne doivent pas être dissimulées selon la norme NFPA 54 et doivent rester accessibles pour permettre leur inspection et réparation. Des caches décoratifs sont disponibles chez Rinnai. Ces illustrations montrent 3 façons possibles d’orienter l’extension de la conduite d’évacuation et du tuyau d’admission d’air en partant du collecteur de fumée.
  • Page 70 être coupés à la longueur voulue. Ébarbez les bords de coupe bruts. Ne coupez pas le tube relié à l’appareil. Supportez le tuyau d’admission d’air à l’aide de colliers de soutien. Rinnai Corporation EX17C / EX22C Manual 1 pouce (25,4 mm) zéro Conduite d’évacuation Exhaust pipe Conduite d’évacuation...
  • Page 71 ⑥ HOSE JOINT JOINT DE TUYAUX ⑪ NUT ÉCROU FOT-201 FOT-219 ensembles Rinnai Corporation EX17C / EX22C Manual TUYAU D’ADMISSION D’AIR AIR INTAKE HOSE ⑦ PIPE STOPPER A ARRÊT DE ARRÊT DE ⑧ PIPE STOPPER B TUYAU A TUYAU B ⑬...
  • Page 72: Branchement De L'appareil

    2 vis. Collecteur de fumée Flue Manifold Pipe stopper Arrêt de tuyau Elbow Coude Rinnai Corporation EX17C / EX22C Manual Crochet Hook Manifold Collecteur Pipe stopper Arrêt de tuyau Fit Clip Positionner l’agrafe...
  • Page 73: Ajustage Et Reglage De La Presion De Gas

    0.54 in 0.60 in (14 mm) (15 mm) 2.0 in 1.8 in (52 mm) (47 mm) Rinnai Corporation EX17C / EX22C Manual Gaz Propane L1 / L5 L2 / L6 L3 / L7 0-2000 ft 2001-5200 ft 5201-7700 ft 0-610 m...
  • Page 74 Assemblée finale 1. Installer le panneau de devant et la couverture de fond. 2. Si vous faites une conversion de type de gaz, placer la nouvelle plaque de conversion (étiquette) sur le capot avant. Rinnai Corporation EX17C / EX22C Manual...
  • Page 75: Instructions De Mise En Œuvre

    Consultez le manuel pour plus d'informations. REMARQUE : Le ventilateur va continuer de tourner jusqu’au Rinnai Corporation EX17C / EX22C Manual refroidissement de l’appareil. Ne coupez pas l’appareil en débranchant la fiche de la prise secteur.
  • Page 76: Schéma En Coupe

    Schéma en coupe Rinnai Corporation EX17C / EX22C Manual...
  • Page 77: Schéma De Câblage

    SV1, 2 ÉLECTROVANNE 1,2 MOTEUR DE VENTILATEUR DE COMBUSTION DÉTECTEUR DE PRESSION UNITÉ AFFICHAGE-COMMANDE Rinnai Corporation EX17C / EX22C Manual Si des fils d’origine livrés avec l’appareil ont besoin d’être remplacés, choisissez un fil de calibre 18 AWG ou équivalent. CODE...
  • Page 78: Diagramme Logique

    Diagramme logique Rinnai Corporation EX17C / EX22C Manual...
  • Page 79: Service À La Clientèle

    Rinnai paiera dans les limites du raisonnable le coût de main-d’œuvre associé à la réparation ou au remplace- ment de toute partie ou composant. Toutes les pièces à réparer doivent être des pièces Rinnai d’origine. Toutes les ré- parations et tous les replacements doivent être effectués par un dépanneur individuel ou une société de dépannage ayant reçu l’autorisation de Rinnai.
  • Page 80: Garantie Limitée

    Garantie limitée (Suite) Le remplacement du produit ne peut être autorisé que par Rinnai. La société Rinnai ne permet à aucune personne ou société d’assumer pour elle toute obligation ou responsabilité relative au remplacement d’un produit. Si Rinnai détermine que la réparation d’un produit n’est pas possible, Rinnai le remplacera avec un produit comparable, à...
  • Page 81 Notes Rinnai Corporation EX17C / EX22C Manual...
  • Page 82 Notes Rinnai Corporation EX17C / EX22C Manual...
  • Page 83 Notes Rinnai Corporation EX17C / EX22C Manual...
  • Page 84 RHF559-1232X01(00) Printed in Japan 2010.06...

Table of Contents