Removal And Replacement Of Spray Tubes - Hoshizaki KM-1340MAH Service Manual

Modular crescent cuber
Hide thumbs Also See for KM-1340MAH:
Table of Contents

Advertisement

4) Replace the removed parts in their correct positions.
5) Disconnect the pump suction and discharge hoses.
6) Remove the screws and the pump motor bracket.
7) Remove the closed end connectors from the pump motor leads.
8) Remove the two screws and the pump motor bracket.
9) Remove the pump housing, and check the impeller.
10) If the impeller is defective, install a new impeller.
11) Install the new motor or new parts, and replace the removed parts in the reverse order
of which they were removed.
12) Turn on the power supply, and check for leaks.
13) Replace the front panel in its correct position.
O. Removal and Replacement of Spray Tubes
1) Turn off the power supply.
2) Remove the front panel and the insulation panel.
3) Remove the rubber hoses from the spray tubes (water supply pipe).
4) Release the clamps, and disconnect the rubber hoses.
5) Remove the spray tubes by squeezing the side tabs.
6) Install the new spray tubes, and replace the removed parts in the reverse order of which
they were removed.
7) Replace the panels in their correct positions.
8) Turn on the power supply.
50

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Km-1340mwhKm-1340mrh

Table of Contents