3. KM-1340MRH (remote air-cooled)

APPROXIMATE ICE
PRODUCTION PER 24 HR.
lbs./day kg./day
APPROXIMATE ELECTRIC
CONSUMPTION
watts
APPROXIMATE WATER
CONSUMPTION PER 24 HR.
3
gal./day
m
/day
FREEZING CYCLE TIME
min.
HARVEST CYCLE TIME
min.
HEAD PRESSURE
2
PSIG
kg/cm
G
SUCTION PRESSURE
2
PSIG
kg/cm
G
TOTAL HEAT OF REJECTION FROM CONDENSER
TOTAL HEAT OF REJECTION FROM COMPRESSOR
CONDENSER VOLUME
Note:
1. Pressure data is recorded at 5 minutes into freezing cycle. The data not in bold
should be used for reference only.
2. We reserve the right to make changes in specifications and design without prior
notice.
AMBIENT TEMP.
(ºF/ºC)
70/21
1401
80/27
1367
90/32
1357
100/38
1333
70/21
80/27
90/32
100/38
70/21
451
80/27
401
90/32
386
100/38
308
70/21
80/27
90/32
100/38
70/21
80/27
90/32
100/38
208
70/21
80/27
221
90/32
226
100/38
229
44
70/21
80/27
46
90/32
47
100/38
47
32
WATER TEMP. (ºF/ºC)
50/10
70/21
635
1357
620
1299
1251
615
604
1229
2130
2197
2181
2286
2197
2360
2184
2364
1.71
386
1.52
300
229
1.46
1.16
222
25
27
26
29
27
31
27
31
5.5
4.8
5.0
3.9
3.2
4.8
4.0
3.1
14.6
226
15.6
250
15.9
270
16.1
275
3.1
47
3.2
50
53
3.3
3.3
53
20,800 BTU/h [AT 90ºF (32ºC) / WT 70ºF (21ºC)]
3,000 BTU/h [AT 90ºF (32ºC) / WT 70ºF (21ºC)]
134 CU. IN (URC-14F)
90/32
615
1274
578
589
1204
546
567
1159
526
558
1075
488
2231
2287
2376
2390
1.46
344
1.30
1.14
284
1.08
0.87
201
0.76
0.84
175
0.66
29
31
33
35
4.3
3.6
2.8
2.4
15.9
247
17.4
17.6
269
18.9
19.0
290
20.4
19.3
309
21.7
3.3
49
3.4
3.5
51
3.6
3.7
54
3.8
3.7
55
3.9

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Km-1340mwhKm-1340mrh

Table of Contents