9) Pour the cleaning solution over the extruding head until the evaporator assembly and the
reservoir are filled and the solution starts to overflow into the drain pan.
Note: If there is excess scale on the extruding head, fill the evaporator assembly and
reservoir as described above, then use a clamp on the reservoir hose between the
reservoir and evaporator assembly to block flow. Pour additional cleaning fluid
over the extruding head until the evaporator assembly is completely full.
10) Replace the spout and strap in their correct positions.
11) Allow the icemaker to sit for about 10 minutes before operation. If you placed a clamp on
the reservoir hose in step 9, remove it before operation.
12) Move the flush switch to the "ICE" position, then turn on the power supply. Replace the
top panel and front panel in their correct positions. Make ice using the solution until the
icemaker stops making ice.
13) Remove the front panel.
14) Move the flush switch to the "FLUSH" position to drain the remainder of the solution.
15) After the solution is drained, move the flush switch to the "ICE" position.
16) Replace the front panel in its correct position.
17) Open the water supply line shut-off valve and supply water to the reservoir.
18) When the gear motor starts, remove the front panel and turn off the power supply.
19) Drain out all water from the water line. See 4) through 6).

[c] Sanitizing Solution

Dilute 2.5 fl. oz. (74 ml or 5 tbs) of IMS-II Sanitizer or a 5.25% sodium hypochlorite solution
(chlorine bleach) with 5 gallons (19 l) of warm water.
For safety and maximum effectiveness, use the solution immediately after
dilution.

[d] Sanitizing Procedure - Initial

1) Close the water supply line shut-off valve.
2) Remove the strap connecting the spout to the chute assembly.
3) Remove the thumbscrews securing the spout and lift it off. Remove the rubber O-ring and
nylon O-ring at the top of the cylinder and remove the packing between the spout and
chute.
IMPORTANT