STRAIGHT UP
VERTICAL VENTING
V (FT.)
50' MAX. (15.2 M)
NOTE: On vertical venting
configurations you may
want to install the flue re-
strictor (385-128). See flue
restrictor installation in-
structions.
Figure 8
Flue Restrictor Instructions
1. Locate the flue restrictor which is in the manual
bag.
FLUE
RESTRICTOR
Figure 9
2. Break the Flue Restrictor into two pieces. Do this
by bending the part back and forth until it breaks
(see Figure 10).
18
CAP
Quadra-Fire • QV-PIER, QV-ST Series: HV-IPI • 2005-901 Rev. G • 2/06
BREAK
HERE
Figure 10.
Flue Restrictor
3. Match the amount of
vertical you have in the
system with the chart to
find the appropriate po-
sition to set the Flue Re-
strictor.
4. Center the Flue Restrictor on vent and secure in
place using two self-tapping screws (see Figure 11).
Figure 11
STRAIGHT OUT
HORIZONTAL VENTING
H
Max. Run
24" (610 mm)
H
- CHART -
Vertical
Settings
4'
1-1
8'
1-2
15'
2-2
20'
2-3
25'
3-3
30'
4-3
35'
4-4
40'
4-4
50'
4-5
1
2
3
4 5
SETTINGS
1
2
3
4 5
Figure 12.