Troubleshooting

This replace will operate correctly only if adequate ventila-
tion is provided to allow proper draft to the replace system.
Hearth & Home Technologies assumes no responsibility for
the improper performance of the replace system caused
by inadequate draft due to environmental conditions, down
drafts, tight sealing construction of the structure, or mechan-
ical exhausting devices which will create a negative air pres-
sure within the structure where the replace is located.
A. Understanding Vent Problems
If smoke spillage occurs from a replace opening when the
door is open and the proper chimney height, ue size, and
con guration requirements for the installation have been
met, there is either a leakage in the ue, a blockage in the
Figure 10.1 Factory-built Fireplaces: Troubleshooting
32
Heat & Glo • EXCLAIM-36C Woodburning Fireplace • 4013-093 Rev G • 08/06
ue, or some condition is in effect to draw smoke from the
replace into the house. Understanding and differentiating
the conditions which can cause each of these kinds of spill-
age problems is essential to their solution.
Flue Leakage
Check for improperly connected ue joints or a damaged
ue joint in the chimney system. Such leakage would
reduce draft (air would be drawn in through the leaks rather
than through the replace). The result might be dif cult
start-up and smoky res that might spill if other adverse
draft conditions accompany this problem.
Flue Blockage
The damper should be open.