Listing And Code Approvals; Appliance Certifi Cation; Glass Specifi Cations; Btu Specifi Cations - Heat & Glo Soho24B Owner's Manual

Hide thumbs Also See for Soho24B:
Table of Contents

Advertisement

1 1

Listing and Code Approvals

A. Appliance Certifi cation
MODELS: Soho24B
LABORATORY: Underwriters Laboratories, Inc. (UL)
TYPE: Direct Vent Gas Appliance Heater
STANDARD: ANSI Z21.88a-2007 • CSA2.33a-2007
This product is listed to ANSI standards for "Vented Gas
Appliance Heaters" and applicable sections of "Gas
Burning Heating Appliances for Manufactured Homes
and Recreational Vehicles", and "Gas Fired Appliances
for Use at High Altitudes".
NOT INTENDED FOR USE AS A PRIMARY HEAT SOURCE.
This appliance is tested and approved as either supplemen-
tal room heat or as a decorative appliance. It should not be
factored as primary heat in residential heating calculations.
B. Glass Specifi cations
Hearth & Home Technologies appliances manufactured with
tempered glass may be installed in hazardous locations such
as bathtub enclosures as defi ned by the Consumer Product
Safety Commission (CPSC). The tempered glass has been
tested and certifi ed to the requirements of ANSI Z97.1 and
CPSC 16 CFR 1202 (Safety Glazing Certifi cation Council
SGCC# 1595 and 1597. Architectural Testing, Inc. Reports
02-31919.01 and 02-31917.01).
This statement is in compliance with CPSC 16 CFR Section
1201.5 "Certifi cation and labeling requirements" which refers
to 15 U.S. Code (USC) 2063 stating "...Such certifi cate shall
accompany the product or shall otherwise be furnished to
any distributor or retailer to whom the product is delivered."
Some local building codes require the use of tempered glass
with permanent marking in such locations. Glass meeting
this requirement is available from the factory. Please contact
your dealer or distributor to order.
Note: This installation must conform with local codes. In the
absence of local codes you must comply with the National
Fuel Gas Code, ANSI Z223.1-latest edition in the U.S.A. and
the CAN/CGA B149 Installation Codes in Canada.
C. BTU Specifi cations
Models
U.S. (0-2000 ft.) or Canada (2000-4500 ft.)
Soho24 (NG)
Soho24LP
4
Maximum
Minimum
Input BTU/h
Input BTU/h
14,000
N/A
US
12,600
N/A
CAN
13,000
N/A
US
11,700
N/A
CAN
Heat & Glo • Soho24B • 2137-900 Rev. P • 8/12
D. High Altitude Installations
U.L. Listed gas appliances are tested and approved without
requiring changes for elevations from 0 to 2000 feet in the
U.S.A. and Canada.
When installing this appliance at an elevation above 2000
feet, it may be necessary to decrease the input rating by
changing the existing burner orifi ce to a smaller size. Input
rate should be reduced by 4% for each 1000 feet above
a 2000 foot elevation in the U.S.A., or 10% for elevations
between 2000 and 4500 feet in Canada. If the heating value
of the gas has been reduced, these rules do not apply. To
identify the proper orifi ce size, check with the local gas utility.
If installing this appliance at an elevation above 4500 feet (in
Canada), check with local authorities.
Do NOT use this appliance if any part has been under water.
Immediately call a qualifi ed service technician to inspect the
appliance and to replace any part of the control system and
any gas control which has been under water.
E. Non-Combustible Materials Specifi cation
Material which will not ignite and burn. Such materials are
those consisting entirely of steel, iron, brick, tile, concrete,
slate, glass or plasters, or any combination thereof.
Materials that are reported as passing ASTM E 136,
Standard Test Method for Behavior of Materials in a
Vertical Tube Furnace at 750ºC, shall be considered
non-combustible materials.
F. Combustible Materials Specifi cation
Materials made of or surfaced with wood, compressed
paper, plant fi bers, plastics, or other material that can
ignite and burn, whether fl ame proofed or not, or whether
plastered or unplastered shall be considered combustible
materials.
G. Electrical Codes
NOTICE: This appliance must be electrically wired and
grounded in accordance with local codes or, in the absence
Orifi ce
of local codes, with National Electric Code ANSI/NFPA
Size
70-latest edition or the Canadian Electric Code CSA
(DMS)
C22.1.
50
• A 110-120 VAC circuit for this product must be protected
51
with ground-fault circuit-interrupter protection, in compliance
with the applicable electrical codes, when it is installed in
59
locations such as in bathrooms or near sinks.
60
WARNING

Advertisement

Table of Contents
loading

Table of Contents