Finishing; Facing Material; Mantel Projections - Heat & Glo Soho24B Owner's Manual

Hide thumbs Also See for Soho24B:
Table of Contents

Advertisement

11
11

Finishing

A. Facing Material
WARNING
Fire Risk.
Do NOT obstruct air inlet or outlet grilles.
Do NOT modify grilles.
• Modifying or covering grilles could cause
temperature rise and fi re hazard.
Finishing materials must not interfere with:
• Air fl ow through grilles or louvers.
• Operation of louvers or doors.
• Access for service.
FINISH WALL MATERIAL MAY BE
COMBUSTIBLE - TOP AND SIDES
8 in.
31-11/16 in.
0 in.
Figure 11.1 Noncombustible Facing Diagram
WARNING
Risk of Fire
• Non-combustible clearances MUST be
maintained.
• Sheetrock, wood or other combustibles must
NOT be used as sheathing or facing in the
non-combustible zone.
• See Section 11 for proper clearances.
• See Section 1 for combustible/non-combustible
defi nitions.
32
NON-COMBUSTIBLE ZONE
0 in.
SEALANT MATERIAL
Heat & Glo • Soho24B • 2137-900 Rev. P • 8/12
• Black metal appliance front may be covered with
noncombustible material only.
• Do NOT overlap combustible materials onto appliance
front.
• Install combustible materials up to specifi ed clearances
on top, front and side.
• Seal joints between the fi nished wall and appliance top
and sides using only a 300ºF minimum sealant.
B. Mantel Projections
0 in.
A Studio front is required for all installs. No mantels are
allowed when using Studio fronts.
WARNING
Fire Risk.
Finish all edges and fronts to clearances and
specifi cations listed in manual.

Advertisement