Hide thumbs Also See for 6000GL-IPI-S:
Table of Contents

Advertisement

Quick Links

Para obtener un ejemplar en Español de este
Manual del propietario, visite www.heatnglo.com.
Models:
6000GL-IPI-S
6000GL-IPI-R
6000GL-IPILP-S
6000GL-IPILP-R
• Important operating
a n d m a i n t e n a n c e
instructions included.
WARNING: If the information in these
instructions is not followed exactly, a fi re
or explosion may result causing property
damage, personal injury, or death.
• DO NOT store or use gasoline or other fl am-
mable vapors and liquids in the vicinity of this
or any other appliance.
• What to do if you smell gas
- DO NOT try to light any appliance.
- DO NOT touch any electrical switch. DO
NOT use any phone in your building.
- Immediately call your gas supplier from a
neighbor's phone. Follow the gas suppli-
er's instructions.
- If you cannot reach your gas supplier, call
the fi re department.
• Installation and service must be performed
by a qualifi ed installer, service agency, or the
gas supplier.
This appliance may be installed as an OEM installation in
manufactured home (USA only) or mobile home and must be
installed in accordance with the manufacturer's instructions
and the manufactured home construction and safety standard,
Title 24 CFR, Part 3280 or Standard for Installation in Mobile
Homes, CAN/CSA Z240MH, in Canada.
This appliance is only for use with the type(s) of gas indicated
on the rating plate.
NOTICE
DO NOT DISCARD THIS MANUAL
• Read, understand and follow
these instructions for safe
installation and operation.
Heat & Glo • 6000GL-IPI-R, 6000GL-IPI-S • 2102-900 Rev. R • 6/09
Pour demander un exemplaire en français de ce Manuel
du propriétaire, visitez www.heatnglo.com.
Owner's Manual
Installation and Operation
• Leave this manual with
party responsible for use
and operation.
WARNING
HOT SURFACES!
Glass and other surfaces are hot during
operation AND cool down.
Hot glass will cause burns.
• DO NOT touch glass until it is cooled
• NEVER allow children to touch glass
• Keep children away
• CAREFULLY SUPERVISE children in same room as
fi replace.
• Alert children and adults to hazards of high temperatures.
High temperatures may ignite clothing or other fl ammable
materials.
• Keep clothing, furniture, draperies and other fl ammable
materials away.
This appliance has been supplied with an integral barrier
to prevent direct contact with the fi xed glass panel. DO
NOT operate the appliance with the barrier removed.
Contact your dealer or Hearth & Home Technologies if the
barrier is not present or help is needed to properly install one.
In the Commonwealth of Massachusetts installation must be
performed by a licensed plumber or gas fi tter.
See Table of Contents for location of additional Commonwealth
of Massachusetts requirements.
Installation and service of this appliance should be
performed by qualifi ed personnel. Hearth & Home
Technologies suggests NFI certifi ed or factory trained
professionals, or technicians supervised by an NFI
certifi ed professional.
1

Advertisement

Table of Contents
loading

Summary of Contents for Heat & Glo 6000GL-IPI-S

  • Page 1 Technologies suggests NFI certifi ed or factory trained This appliance is only for use with the type(s) of gas indicated professionals, or technicians supervised by an NFI on the rating plate. certifi ed professional. Heat & Glo • 6000GL-IPI-R, 6000GL-IPI-S • 2102-900 Rev. R • 6/09...
  • Page 2: Congratulations

    00,000 00,000 00,000 00,000 MIN. MIN. INPUT INPUT BTUH: BTUH: 00,000 00,000 00,000 00,000 Serial Serial ORIFICE ORIFICE SIZE: SIZE: #XXXXX #XXXXX #XXXXX #XXXXX XXXXXXXX XXXXXXXX (Serie): (Serie): Heat & Glo • 6000GL-IPI-R, 6000GL-IPI-S • 2102-900 Rev. R • 6/09...
  • Page 3: Table Of Contents

    F. Wall Switch Installation for Fan (Optional) ... . 49 A. Vent Termination Minimum Clearances ....21 Heat & Glo • 6000GL-IPI-R, 6000GL-IPI-S • 2102-900 Rev. R • 6/09...
  • Page 4 D. Contact Information ......70 = Contains updated information. Heat & Glo • 6000GL-IPI-R, 6000GL-IPI-S • 2102-900 Rev. R • 6/09...
  • Page 5: Limited Lifetime Warranty

    B. Limited Lifetime Warranty Heat & Glo • 6000GL-IPI-R, 6000GL-IPI-S • 2102-900 Rev. R • 6/09...
  • Page 6 B. Limited Lifetime Warranty (continued) Heat & Glo • 6000GL-IPI-R, 6000GL-IPI-S • 2102-900 Rev. R • 6/09...
  • Page 7: Listing And Code Approvals

    • A 110-120 VAC circuit for this product must be pro- tected with ground-fault circuit-interrupter protection, in compliance with the applicable electrical codes, when it is installed in locations such as in bathrooms or near sinks. Heat & Glo • 6000GL-IPI-R, 6000GL-IPI-S • 2102-900 Rev. R • 6/09...
  • Page 8: Requirements For The Commonwealth Of Massachusetts

    VENT DIRECTLY BELOW. KEEP CLEAR OF ALL OB- of the installation. STRUCTIONS”. See Gas Connection section for additional Common- wealth of Massachusetts requirements. Heat & Glo • 6000GL-IPI-R, 6000GL-IPI-S • 2102-900 Rev. R • 6/09...
  • Page 9: User Guide

    DECORATIVE DOORS (NOT SHOWN) SECTION 2.E. FIXED GLASS ASSEMBLY (NOT SHOWN) SECTION 14.H. MANTEL FAN KIT SECTION 2.C HEARTH CLEAR SPACE SECTION 2.D. Figure 2.1 General Operating Parts Heat & Glo • 6000GL-IPI-R, 6000GL-IPI-S • 2102-900 Rev. R • 6/09...
  • Page 10: Fan Kit (Optional)

    Contact your dealer or Hearth & Home Technologies if the barrier is not present or help is needed to properly install one. For more information refer to the instructions supplied with your decorative door or front. Heat & Glo • 6000GL-IPI-R, 6000GL-IPI-S • 2102-900 Rev. R • 6/09...
  • Page 11: Lighting Instructions (Ipi)

    For additional information on operating your Hearth & Home Technologies fi replace, please refer to www.fi replaces.com. Final inspection by Heat & Glo • 6000GL-IPI-R, 6000GL-IPI-S • 2102-900 Rev. R • 6/09...
  • Page 12: After Fireplace Is Lit

    Is it normal to see the pilot fl ame burn In an IntelliFire ignition system it is normal to see the pilot fl ame, but it should turn off when continually? ON/OFF is turned off. Heat & Glo • 6000GL-IPI-R, 6000GL-IPI-S • 2102-900 Rev. R • 6/09...
  • Page 13: Maintenance And Service

    • Carefully set fi xed glass assembly in place on fi replace. Hold glass in place with one hand and secure glass latches with the other hand. • Reinstall door or decorative front. Heat & Glo • 6000GL-IPI-R, 6000GL-IPI-S • 2102-900 Rev. R • 6/09...
  • Page 14: Maintenance Tasks-Qualifi Ed Service Technician

    fl ame sensing rod. Replace pilot as necessary. • Inspect for paint condition, warped surfaces, corrosion or perforation. Sand and repaint as necessary. Heat & Glo • 6000GL-IPI-R, 6000GL-IPI-S • 2102-900 Rev. R • 6/09...
  • Page 15 Figure 3.1 IPI Pilot Flame Patterns Heat & Glo • 6000GL-IPI-R, 6000GL-IPI-S • 2102-900 Rev. R • 6/09...
  • Page 16: Installer Guide

    FRAMING HEADED OFF IN CEILING JOISTS (SECTION 8.C) OPTIONAL WALL SWITCH MANTEL AND MANTEL LEG (SECTION 5.D) SURROUND HEARTH EXTENSION GAS LINE (SECTION 11) Figure 4.1 Typical System Heat & Glo • 6000GL-IPI-R, 6000GL-IPI-S • 2102-900 Rev. R • 6/09...
  • Page 17: Design And Installation Considerations

    Reciprocating saw Manometer Flat blade screwdriver Non-corrosive leak check solution 1/2 - 3/4 in. length, #6 or #8 Self-drilling screws One 1/4 in. female connection (for optional fan). Heat & Glo • 6000GL-IPI-R, 6000GL-IPI-S • 2102-900 Rev. R • 6/09...
  • Page 18: Framing And Clearances

    REAR VENT, HORIZONTAL TERMINATION, ONE ELBOW TWO ELBOWS REAR VENT, NO ELBOWS Inches 56-5/8 17-3/4 See Section D. Mantel Projections Millimeters 1295 1067 1829 1438 Figure 5.1 Appliance Locations Heat & Glo • 6000GL-IPI-R, 6000GL-IPI-S • 2102-900 Rev. R • 6/09...
  • Page 19: Constructing The Appliance Chase

    Millimeters 1067 * Adjust framing dimensions for interior sheathing (such as sheetrock) C** Add 12 inches for rear venting with one 90º elbow. Figure 5.2 Clearances to Combustibles Heat & Glo • 6000GL-IPI-R, 6000GL-IPI-S • 2102-900 Rev. R • 6/09...
  • Page 20: Mantel And Wall Projections

    Note: All measurements in inches. Note: Measurement is taken from top of the opening, NOT the top of the fi replace. Figure 5.3 Minimum Vertical and Maximum Horizontal Dimensions of Combustibles Heat & Glo • 6000GL-IPI-R, 6000GL-IPI-S • 2102-900 Rev. R • 6/09...
  • Page 21: Termination Locations

    Over 16/12 to 18/12 ..........7.0 Over 18/12 to 20/12 ..........7.5 Over 20/12 to 21/12 ..........8.0 * 3 foot minimum in snow regions Figure 6.1 Minimum Height From Roof To Lowest Discharge Opening Heat & Glo • 6000GL-IPI-R, 6000GL-IPI-S • 2102-900 Rev. R • 6/09...
  • Page 22 Figure 6.3 Minimum Clearances for Termination CAUTION: IF EXTERIOR WALLS ARE FINISHED WITH VINYL SIDING, IT IS SUGGESTED THAT A VINYL PROTECTOR KIT BE INSTALLED. Heat & Glo • 6000GL-IPI-R, 6000GL-IPI-S • 2102-900 Rev. R • 6/09...
  • Page 23: Vent Information And Diagrams

    76 to 152 DVP12A 3 to 12 76 to 305 DVP12MI 3 to 12 76 to 305 DVP24MI 3 to 24 76 to 610 Figure 7.2 DVP Pipe Effective Length Heat & Glo • 6000GL-IPI-R, 6000GL-IPI-S • 2102-900 Rev. R • 6/09...
  • Page 24: Vent Diagrams

    18 ft. 5.5 m 5 ft. 1.5 m 20 ft. 6.1 m = 40 ft. (12.2 m) Maximum = 20 ft. (6.1 m) Maximum INSTALLED HORIZONTALLY Figure 7.4 Heat & Glo • 6000GL-IPI-R, 6000GL-IPI-S • 2102-900 Rev. R • 6/09...
  • Page 25 914 mm 16 ft * 4.9 m* 3 ft. 914 mm 14 ft.* 4.3 m* = 20 ft. (6.1 m) Maximum = 40 ft. (12.2 m) Maximum Figure 7.5 Heat & Glo • 6000GL-IPI-R, 6000GL-IPI-S • 2102-900 Rev. R • 6/09...
  • Page 26 2. Break the fl ue restrictor into two pieces. Do this by bending the part back and forth until it breaks (see Figure 7.8). BREAK HERE Figure 7.6 Figure 7.8 Flue Restrictor Heat & Glo • 6000GL-IPI-R, 6000GL-IPI-S • 2102-900 Rev. R • 6/09...
  • Page 27 1.2 m 20 ft 6.1 m = 50 ft (15.2 m) Maximum *No specifi c restrictions on this value EXCEPT cannot exceed 50 ft (15.2 m) Figure 7.11 Heat & Glo • 6000GL-IPI-R, 6000GL-IPI-S • 2102-900 Rev. R • 6/09...
  • Page 28 4 ft. 1.2 m 18 ft. 5.5 m 18 ft. 5.5 m = 20 ft (6.1 m) Maximum = 40 ft (12.2 m) Maximum INSTALLED HORIZONTALLY Figure 7.12 Heat & Glo • 6000GL-IPI-R, 6000GL-IPI-S • 2102-900 Rev. R • 6/09...
  • Page 29 = 16 in. (406 mm) Maximum No Elbow Figure 7.13 One 45º Elbow Do not use a 45º elbow in corner installations. Use two 90º elbows instead. Figure 7.14 Heat & Glo • 6000GL-IPI-R, 6000GL-IPI-S • 2102-900 Rev. R • 6/09...
  • Page 30 12 ft. 3.7 m 15 ft. 4.6 m = 40 ft (12.2 m) Maximum = 3 ft (914 mm) Maximum = 20 ft (6.1 m) Maximum Figure 7.16 Heat & Glo • 6000GL-IPI-R, 6000GL-IPI-S • 2102-900 Rev. R • 6/09...
  • Page 31 12 ft. 3.7 m 8 ft. 2.4 m 15 ft. 4.6 m = 40 ft (12.2 m) Maximum = 8 ft (2.4 m) Maximum INSTALLED HORIZONTALLY Figure 7.18 Heat & Glo • 6000GL-IPI-R, 6000GL-IPI-S • 2102-900 Rev. R • 6/09...
  • Page 32 = 40 ft. (12.2 m) Maximum *No specifi c restrictions on this value EXCEPT cannot exceed 40 ft. (12.2 m) Maximum = 8 ft. (2.4 m) Maximum INSTALLED Figure 7.20 HORIZONTALLY Heat & Glo • 6000GL-IPI-R, 6000GL-IPI-S • 2102-900 Rev. R • 6/09...
  • Page 33: Vent Clearances And Framing

    (1) in. (25.4 mm) above the center of the horizontal vent pipe. Figure 8.2 Wall Penetration Note: When terminating horizontally off the top of the unit using SLP pipe, a 10 in. x 10 in. framing hole is required. Heat & Glo • 6000GL-IPI-R, 6000GL-IPI-S • 2102-900 Rev. R • 6/09...
  • Page 34: Install The Ceiling Firestop

    INSTALL ATTIC INSULATION SHIELDS BEFORE OR AFTER INSTALLATION OF VENT SYSTEM 3 FASTENERS PER SIDE CEILING FIRESTOP CEILING FIRESTOP INSTALLED BELOW CEILING INSTALLED ABOVE CEILING Figure 8.4 Installing the Attic Shield Heat & Glo • 6000GL-IPI-R, 6000GL-IPI-S • 2102-900 Rev. R • 6/09...
  • Page 35: Install Attic Insulation Shield

    • Bend all tabs inward 90º around the top of the shield. These tabs must be used to prevent blown insulation from getting between the shield and vent pipe, and to Figure 8.6 maintain air space clearance. Heat & Glo • 6000GL-IPI-R, 6000GL-IPI-S • 2102-900 Rev. R • 6/09...
  • Page 36: Appliance Preparation

    Figure 9.6 Remove the insulation from the outer vent Figure 9.3 Remove the white gasket material covering pipe. For rear venting there is no insulation in the outer the seal cap. vent pipe. Heat & Glo • 6000GL-IPI-R, 6000GL-IPI-S • 2102-900 Rev. R • 6/09...
  • Page 37: Rear Vent

    Slide the insulation gasket onto the vent section, Figure 9.9 Cut the metal retaining band and fold the up against the appliance and over the tabs. sides out. Heat & Glo • 6000GL-IPI-R, 6000GL-IPI-S • 2102-900 Rev. R • 6/09...
  • Page 38: Installing The Non-Combustible Board

    • Secure the appliance to the fl oor by inserting two screws through the pilot holes at the bottom of the appliance. NAILING TABS (BOTH SIDES) PILOT HOLES Figure 9.14 Proper Positioning and Securing of an Appliance Heat & Glo • 6000GL-IPI-R, 6000GL-IPI-S • 2102-900 Rev. R • 6/09...
  • Page 39: Installing Vent Pipe (Dvp And Slp Pipe)

    fl ue at the horizontal elbow joint to prevent the elbow from rotating. Use screws no longer than 1/2 in. (13 mm). If predrilling screw holes, DO NOT penetrate inner pipe. INCORRECT Figure 10.4 Seams Heat & Glo • 6000GL-IPI-R, 6000GL-IPI-S • 2102-900 Rev. R • 6/09...
  • Page 40: Assemble Vent Sections (Slp Pipe Only)

    • Only outer pipes are sealed, sealing the inner fl ue is not Figure 10.5 Adding Venting Components required. • All unit collar, pipe, slip section, elbow and cap outer fl ues shall be sealed. Heat & Glo • 6000GL-IPI-R, 6000GL-IPI-S • 2102-900 Rev. R • 6/09...
  • Page 41: Secure The Vent Sections

    Figure 10.10 Rotate Seams for Disassembly connection point to appliance. 120º Figure 10.11 Align and Disassemble Vent Sections Figure 10.8 Securing Vertical Pipe Sections 120º Figure 10.9 Securing Horizontal Pipe Sections Heat & Glo • 6000GL-IPI-R, 6000GL-IPI-S • 2102-900 Rev. R • 6/09...
  • Page 42: Install Decorative Ceiling Components (Slp Only)

    fl aps and the roof. WARNING! Risk of Fire! Clean out ALL materials from Figure 10.13 inside the support box and complete the vertical vent run and termination. Heat & Glo • 6000GL-IPI-R, 6000GL-IPI-S • 2102-900 Rev. R • 6/09...
  • Page 43: Install Metal Roof Flashing

    • Caulk the perimeter of the fl ashing where it contacts the roof surface. See Figure 10.15. Figure 10.17 Assembling the Storm Collar Around the Pipe Figure 10.17 Assembling the Storm Collar Around the Pipe Heat & Glo • 6000GL-IPI-R, 6000GL-IPI-S • 2102-900 Rev. R • 6/09...
  • Page 44: Install Vertical Termination Cap

    • Once the pipe section and the termination cap have been connected, slide the wall thimble up to the interior wall surface and attach with screws provided. See Figure 10.19. Figure 10.19 Wall Thimble Heat & Glo • 6000GL-IPI-R, 6000GL-IPI-S • 2102-900 Rev. R • 6/09...
  • Page 45: Install Horizontal Termination Cap (Dvp And Slp Pipe)

    DVP-TRAP1 can adjust 1-1/2 in. (3-1/8 to 4-5/8 in.) DVP-TRAP2 can adjust 4 in. (5-3/8 to 9-3/8) DVP-HPC1 can adjust 2-1/8 in. (4-1/4 to 6-3/8) DVP-HPC2 can adjust 4-1/8 in. (6-3/8 to 10-1/2) Heat & Glo • 6000GL-IPI-R, 6000GL-IPI-S • 2102-900 Rev. R • 6/09...
  • Page 46: Gas Information

    fl exible gas connector are connected to the 1/2 in. (13 mm) control valve inlet. • If substituting for these components, please consult local codes for compliance. Heat & Glo • 6000GL-IPI-R, 6000GL-IPI-S • 2102-900 Rev. R • 6/09...
  • Page 47: Electrical Information

    Wiring for optional Hearth & Home Technologies approved accessories should be done now to avoid reconstruction. Follow instructions that come with those accessories. Heat & Glo • 6000GL-IPI-R, 6000GL-IPI-S • 2102-900 Rev. R • 6/09...
  • Page 48: Electrical Service And Repair

    WARNING! Risk of Shock! Label all wires prior to dis- insulation. connection when servicing controls. Wiring errors can cause improper and dangerous operation. Verify proper operation after servicing. Heat & Glo • 6000GL-IPI-R, 6000GL-IPI-S • 2102-900 Rev. R • 6/09...
  • Page 49: Junction Box Installation

    Figure 12.3 Junction Box Wired to Wall Switch or BC10 (1/4 in. male) as shown. Heat & Glo • 6000GL-IPI-R, 6000GL-IPI-S • 2102-900 Rev. R • 6/09...
  • Page 50: Finishing

    2-7/16 3-7/16 4-7/16 5-7/16 6-7/16 7-7/16 Inches Millimeters ∞ Inches ∞ Millimeters Figure 13.2 Combustible Mantel Leg or Wall Projections (Acceptable on both sides of opening) Heat & Glo • 6000GL-IPI-R, 6000GL-IPI-S • 2102-900 Rev. R • 6/09...
  • Page 51: Doors

    Finishing material between 1 and 3 inches thick. Figure 13.7 Operable hinge door Finishing materials 1 inch maximum thick. Stop fi nishing material fl ush with opening. Figure 13.5 Overlap Fit Door Heat & Glo • 6000GL-IPI-R, 6000GL-IPI-S • 2102-900 Rev. R • 6/09...
  • Page 52: Appliance Setup

    fi replace. Once in place push it back so the bevel cuts sit against each other and the seam is minimized. Figure 14.1 Figure 14.3 STEP 3. Repeat step 2 for the right side. Heat & Glo • 6000GL-IPI-R, 6000GL-IPI-S • 2102-900 Rev. R • 6/09...
  • Page 53: Ember Placement

    Use this material to give the appliance a realistic ash bed. • Save the remaining ember materials for use during appliance servicing. The embers provided should be enough for 3 to 5 applications. Heat & Glo • 6000GL-IPI-R, 6000GL-IPI-S • 2102-900 Rev. R • 6/09...
  • Page 54: Install The Log Assembly

    Place log #2 on top of log #1. The bottom side of this log has a slot in it that goes over the left metal tab sticking up out of the top of log #1. The left end of this log sits on the burner surface. 2102-910 Heat & Glo • 6000GL-IPI-R, 6000GL-IPI-S • 2102-900 Rev. R • 6/09...
  • Page 55 #1. The thin end of the log rests in the fl at spot molded into the top of log #3. Heat & Glo • 6000GL-IPI-R, 6000GL-IPI-S • 2102-900 Rev. R • 6/09...
  • Page 56: Fixed Glass Assembly

    Air Shutter Settings Figure 14.18 Fixed Glass Assembly I. Install the Mesh Burner 3/16 in. Open 3/8 in. 3/8 in. Screen mesh is supplied with the optional doors. Heat & Glo • 6000GL-IPI-R, 6000GL-IPI-S • 2102-900 Rev. R • 6/09...
  • Page 57: Troubleshooting

    Verify module is securely grounded to metal chassis of appliance. D. Module voltage output / Valve/Pilot Verify battery voltage is at least 2.7 volts. Replace batteries if volt- solenoid ohms readings. age is below 2.7. Heat & Glo • 6000GL-IPI-R, 6000GL-IPI-S • 2102-900 Rev. R • 6/09...
  • Page 58 ON position. If there is no spark at “I” terminal module must be replaced. If there is a spark at “I” terminal, module is fi ne. Heat & Glo • 6000GL-IPI-R, 6000GL-IPI-S • 2102-900 Rev. R • 6/09...
  • Page 59: Reference Materials

    Location Inches Millimeters Location Inches Millimeters 1041 11-5/8 28-1/2 36-1/8 33-1/2 14-1/4 8 dia 34-5/8 2-3/8 2-1/8 6-7/8 26-7/8 6 dia 21-1/2 39-3/8 1000 Figure 16.1 Appliance Dimensions Heat & Glo • 6000GL-IPI-R, 6000GL-IPI-S • 2102-900 Rev. R • 6/09...
  • Page 60: Vent Components Diagrams

    14 in. (356 mm) 5 in. 12 in. (127 mm) (305 mm) 6 in. (152 mm) DVP-HVS (Vent Support) DVP-WS (Wall Shield Firestop) Figure 16.2 DVP vent components Heat & Glo • 6000GL-IPI-R, 6000GL-IPI-S • 2102-900 Rev. R • 6/09...
  • Page 61 79 mm 117 mm Length DVP-TRAP 5-3/8 in. 9-3/8 in. Trap2 Horizontal Termination Cap 137 mm 238 mm DVP-TRAP2 DVP-TRAP1 DVP-TRAPK2 DVP-TRAPK1 DVP-HPC1 DVP-HPC2 Figure 16.3 DVP vent components Heat & Glo • 6000GL-IPI-R, 6000GL-IPI-S • 2102-900 Rev. R • 6/09...
  • Page 62 13-7/8 in. 9-1/2 in. 26 in. (352 mm) (241 mm) 660 mm 14 in. (356 mm) DVP-HSM-B Extended Heat Shield DRC-RADIUS Figure 16.4 DVP vent components Cap Shield Heat & Glo • 6000GL-IPI-R, 6000GL-IPI-S • 2102-900 Rev. R • 6/09...
  • Page 63 1 in. (25 mm) (222 mm) 7-3/4 to 10-3/8 in. (197 to 264 mm) 1-5/8 in. (41 mm) DVP-FBHT FireBrickTermination Cap DVP-HPC High Performance Cap Figure 16.5 DVP vent components Heat & Glo • 6000GL-IPI-R, 6000GL-IPI-S • 2102-900 Rev. R • 6/09...
  • Page 64 SS termination caps on top vented fi replaces, a 6 inch minimum vertical vent section is required before installing fi rst elbow. DVP-HRC-SS DVP-HRC-ZC-SS HORIZONTAL TERMINATION CAP Figure 16.6 DVP vent components Heat & Glo • 6000GL-IPI-R, 6000GL-IPI-S • 2102-900 Rev. R • 6/09...
  • Page 65 51 - 152 SLP12A 2 - 12 51 - 305 SLP PIPE SLP-HVS SLP-FS SLP-WS Horizontal Pipe Ceiling Firestop Wall Shield Firestop Support Figure 16.7 SLP Series Vent Components Heat & Glo • 6000GL-IPI-R, 6000GL-IPI-S • 2102-900 Rev. R • 6/09...
  • Page 66 660 mm DVP-HSM-B DVP-2SL Extended Heat Shield SLP-DCF-BK SLP-WT-BK PVK-80 Ceiling Firestop Wall Thimble-Black (For use with IPI and DSI appliances only.) Black Figure 16.8 SLP Series Vent Components Heat & Glo • 6000GL-IPI-R, 6000GL-IPI-S • 2102-900 Rev. R • 6/09...
  • Page 67: Service Parts

    6748942, 6769426, 6774802, 6796302, 6840261, 6848441, 6863064, 6866205, 6869278, 6875012, 6880275, 6908039, 6919884, D320652, D445174, D462436; (Canada) 1297749, 2195264, 2225408, 2313972; (Australia) 780250, 780403, 1418504 or other U.S. and foreign patents pending. Printed in U.S.A. - Copyright 2009 Heat & Glo • 6000GL-IPI-R, 6000GL-IPI-S • 2102-900 Rev. R • 6/09...

This manual is also suitable for:

6000gl-ipilp-s6000gl-ipilp-r6000gl-ipi-r

Table of Contents