Heat & Glo ST-36TR-IPI Owner's Manual page 53

Hide thumbs Also See for ST-36TR-IPI:
Table of Contents

Advertisement

Wiring the Wall Switch
• Install the provided control wire from the fi replace to the
switch location. (Control wire for Heatilator products is
supplied with the fi replace).
NOTICE: Do not to stress the wire around tight or sharp
corners. Do not run the control wire adjacent to existing or
future phone, data, cable, or electrical lines. The wire should
not come into contact with any part of the fi replace exterior
with the exception of where it exits the outer wrap.
ORANGE
GROUND
BLACK
IPI
VALVE
FLAME
SOLENOID
ADAPTER WIRES
EMBER LIGHT
CONNECTOR BLOCK
SEE DETAIL IN FIGURE 12.3
Figure 12.2 Intellifi re (IPI) Wiring Diagram
BLACK
WHITE
BROWN
GREEN
1
2
IPI
3
MODULE
4
5
6
7
8
3V DC
RED
FLAME ON
RED
FLAME HIGH/LOW
AC
PLUG
AUX
CONNECTION
Heat & Glo • ST-36TR-IPI, PIER-36TR-IPI • 2176-900 Rev. G • 3/13
• Feed the wire to the electrical junction box and through
a provided or approved strain relief.
• Connect the wires to the terminals as shown in Figure
12.2. Do not over-tighten.
• Using the screws provided, mount the switch to the
electrical junction box right side up.
• Install provided cover plate using the screws provided.
Do not use a substitute cover even though it may fi t. The
provided one is specifi cally designed for the automatic
(thermostat) function of the unit.
BATTERIES
* May be labeled as "W" or "Y".
BLACK
RED
YELLOW OR
WHITE
*
BROWN
BROWN
RED
BLACK
ORANGE
ORANGE
BLACK
BLACK
GROUND PIGTAIL
GREEN
RED
REAR VIEW
GREEN
*
FRONT VIEW
(FEMALE/FEMALE)
YELLOW
YELLOW
FAN THERMOSTAT
BLACK
FAN
CONNECTION
TEMPERATURE
SENSOR SWITCH
FAN CORD
BLACK
53

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

St-36trlp-ipiPier-36tr-ipiPier-36trlp-ipi

Table of Contents