Heat & Glo ST-36TR-IPI Owner's Manual page 31

Hide thumbs Also See for ST-36TR-IPI:
Table of Contents

Advertisement

2. Break the exhaust restrictor into two pieces. Do this
by bending the part back and forth until it breaks (see
Figure 7.9).
BREAK
HERE
Figure 7.9 Exhaust Restrictor
3. Match the amount of vertical you have in the system
with the chart to fi nd the appropriate position to set the
exhaust restrictor (see Figure 7.10).
TOP VENT
Vertical
NG
4 ft.
1-1
Restrictor
8 ft.
2-2
15 ft.
3-3
20 ft.
3-4
25 ft.
3-4
30 ft.
4-4
35 ft.
4-4
40 ft.
5-4
45 ft.
5-4
50 ft.
5-5
55 ft.
5-5
Note: If the DVP-2SL adapter and SLP pipe is used, you
MUST subtract one number from the table above.
Example: Top vent 40 ft vertical with DVP pipe = 5-4
Top vent 40 ft vertical with SLP pipe = 4-3
REAR VENT
LP
NG
LP
No
No
No
Restrictor
Restrictor
No
1-2
1-1
Restrictor
3-2
2-2
1-2
3-3
3-3
2-3
3-3
3-3
2-3
3-4
3-4
3-3
3-4
3-4
3-3
4-4
4-4
3-4
4-4
4-4
3-4
5-4
5-4
4-4
5-4
5-4
4-4
Heat & Glo • ST-36TR-IPI, PIER-36TR-IPI • 2176-900 Rev. G • 3/13
4. Center the exhaust restrictor in the open end of the ex-
haust outlet and secure through the slots on the exhaust
restrictor with the 2-1/4 in. self tapping screws provided
in the appliance manual bag.
5. Reinstall the refractory panel.
Figure 7.10
1
2
3
4 5
SETTINGS
1
2
3
4 5
31