VENT PIPING FOR NON-DIRECT
VENT (1 PIPE) APPLICATIONS
MAXIMUM ALLOWABLE
VENT PIPE LENGTH (FT)
ALTITUDE
ABOVE
SEA
LEVEL
(FT)
0 to 2000
200I
to 3000
300I to 4000
400I to 50001-
UNIT SIZE
024040
036040
024060
036060
048060
036080
048080
060080
048100
060100
060120
024040
036040
024060
036060
048060
036080
048080
060080
048100
060100
060120
024040
036040
024060
036060
048060
036080
048080
060080
048100
060100
060120
024040
036040
024060
036060
048060
036080
048080
060080
048100
060100
060120
* Wide radius elbow.
VENT PIPE
DIAMETER
(IN.)*
I
1-1/2
2
1-1/2
2
1-1/2
2
2-1/2
2
2-1/2
3
2-1/2 one disk
31-
31-no disk
41- no disk
1-1/2
2
1-1/2
2
2
2-1/2
2-1/2
3
3
31-no disk
41- no disk
1-1/2
2
1-1/2
2
2
2-/I2
2-1/2
3
31-no disk
41- no disk
1-1/2
2
1-1/2
2
2
2-1/2
2-1/2
3
31-no disk
41- no disk
1
5
7O
7O
2O
7O
I0
55
7O
5
4O
7O
I0
45
7O
7O
67
7O
I7
7O
49
7O
35
7O
I4
7O
7O
64
7O
I6
68
46
7O
33
7O
65
7O
6O
7O
I5
64
44
7O
31
7O
53
7O
2
NA
7O
7O
I5
7O
NA
5O
7O
NA
3O
7O
NA
4O
7O
7O
62
7O
I2
67
44
7O
26
7O
9
7O
7O
59
7O
I1
63
41
7O
24
7O
58
7O
55
7O
I0
59
39
7O
22
7O
46
7O
NUMBER OF 90 ° ELBOWS
3
4
NA
NA
65
60
70
70
I0
5
70
70
NA
NA
35
30
70
70
NA
NA
20
20
70
70
NA
NA
35
30
70
70
70
70
57
52
70
70
7
NA
66
61
30
25
70
70
I6
I6
70
70
NA
NA
63
56
70
70
54
49
70
70
6
NA
62
57
28
23
70
70
I5
I4
70
66
51
44
70
70
50
45
70
70
5
NA
58
53
26
21
70
70
I3
I2
67
62
40
33
70
70
5
NA
6O
7O
NA
7O
NA
3O
7O
NA
10
7O
NA
25
7O
7O
52
7O
NA
6I
25
7O
6
66
NA
50
7O
48
7O
NA
57
22
7O
5
6I
38
7O
44
7O
NA
52
2O
7O
NA
57
26
7O
1- Vent sizing for Canadian
installations
above 4500 ft (1370m)
above
sea level are subject to acceptance
by the local authorities
having
jurisdiction.
NA -- Not Allowed.
Pressure
switch will not make.
NOTES:
I1
D_ n_t use pipe size greater than th_se
speci_ed
in tabIe _r inc_mp_ete
c_mbusti_n,
f_ame disturbance_
_r f_ame sense l_ck_ut
may _ccur`
2.
Assume
two 45 ° elbows
equal
one 90 ° elbow. Long radius elbows
are desirable
and may be required
in some cases.
3.
Elbows
and pipe sections
within
the furnace
casing and at the vent termination
should
not be included
in vent length or elbow
count.
4.
The minimum
pipe length is 5 ft for all applications.
6
NA
55
70
NA
70
NA
20
70
NA
NA
70
NA
20
70
70
47
70
NA
6I
15
7O
NA
6I
NA
43
7O
43
7O
NA
56
13
7O
NA
56
3I
7O
39
7O
NA
52
1I
7O
NA
52
2O
7O
ml0m

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents