P42DF* Indoor Gas Fireplace
45° Corner Installation.
Attach an PEL-45 (45° elbow) directly onto the flue collar. Cut the PXT-
20 to suit, and attach it to the PEL-45. Slide the fireplace into position
and attach to the termination.
Figure 15. Corner (Rigid) installation. (NG Models Only)
Page 14
Installation
45° or less Corner Installation.
Use an PTO-4 termination and an PFL-1 or PFL-2 (12" or 24"
compressed length) and a frame, if appropriate. Flex may be turned
to obtain desired degree of angle required but must not exceed 45°.
PXT-18
PEL-45 Elbow
PEL-90 Elbow
Figure 15a. Corner (Flex) installation. (NG Models Only)
Note: Through the wall venting kits are also available for both
the Straight and the Corner Installation. The Kit includes a heat
shield, a PFL-18 (f/f) flexible pipe, and a termination with or without
a mounting frame.
Corner Installation is available for P42DF
Top Vent Units Only. Ensure minimum
Vertical Venting Height of 48" is maintained
IMPORTANT:
in corner installations.
XG0195 - 030712.1