Electrical test
Before assemby all electrical parts MUST be checked for safety, and that they conform to specification.
Testing the Armature (Flash Testing)
A
Armature shaft to lamination pack
B
Lamination pack to commutator
C
Armatuure shaft to commutator
ELECTRICAL PERFORMANCE TEST READINGS
MODEL
840S
840S
840S
Measured on disassembly/assembly 40/50ft lbs 47/61Nm. (Non Electrical Test)
Note: On all test readings + or -5% of figures shown is acceptable.

ELECTRICAL TESTING

ARMATURES
110V
.440/.506 Ohms
FIELD COILS
110V
.349/.401 Ohms
PERFORMANCE
Running No Load
110V
4.5/6.5 Amps
CLUTCH SLIP
Service and Repair Manual
Model 840S
1500 Volts (min)
1200 Volts (min)
3000 Volts (min)
120V
.440/.506 Ohms
120V
.349/.401 Ohms
120V
4.5/6.5 Amps
220V-240V
1.283/1.477 Ohms
220V-240V
1.339/1.54 Ohms
220V-240V
2.9/4.4 Amps