F. Electrical Connection
1. Electrical connections must be made in accordance with the instructions on
the "WARNING" tag, provided with the pig tail leads in the junction box.
2. Electrical connections must meet national, state, and local electrical code
requirements. Failure to meet these code requirements could cause severe
injury to individuals or extensive damage to equipment.
3. Be sure to install a proper ground to the icemaker.
4. When installing a remote air-cooled model, the power supply and ground wire
to the condenser unit are supplied from the icemaker. See "G.5. Electrical
Connection."
5. To reduce the risk of electric shock, do not connect the power supply until
after all condenser unit connections have been made.
6. On remote air-cooled model, the icemaker should have power for a minimum
of 4 hours prior to startup to prevent compressor damage.
• Electrical connections must be installed in accordance with applicable national, state, and
local regulations.
• Usually an electrical permit and services of a licensed electrician are required.
• The icemaker requires an independent power supply. See the nameplate for proper
voltage and breaker/fuse size.
• The maximum allowable voltage variation is ±10 percent of the nameplate rating.
• The voltage tap switch in the unit must be positioned to match incoming voltage at startup.
See Fig. 8.
• The opening for the power supply connection is 7/8" DIA to fit a 1/2" trade size conduit.
WARNING